If you’re looking for a replacement for a GE vivid7 ultrasound probe, you’ve come to the right place. For some time, the GE Vivid 7 was the best selling midrange cardiac ultrasound machine in the world. It was known for its image management, quantitative tool sets, and premium image quality. While the machine is no longer manufactured, you can still find used versions for sale in great condition.GE Vivid 7 Probe
GE 7S-RS probe
A GE 7S-RS compatible probe is a sector transducer that works perfectly with GE ultrasound systems. Its frequency range is 3.5-8.0 MHz, and it supports 2D, color, and PW & CW doppler imaging. This probe is compatible with a wide range of GE ultrasound machines, including the Vivid I, q, S5, and S6. It also comes with a 90-day manufacturer warranty.
The M4S-RS ultrasound probe features a unique ergonomic design that minimizes strain while using it. Its lightweight cable allows the sonographer to position the transducer without breaking the sterile field. With this probe, the sonographer can also use the linear transducer as a remote control, which decreases exam time and strain for both the patient and the sonographer. It is compatible with GE’s new GE Logiq e NextGen portable ultrasound system.GE Vivid 7 Probe
GE 12L-RS probe
The GE 12L-RS Linear Array Ultrasound Probe is a very good linear transducer for ultrasound imaging. This probe has a frequency range of 5.0 MHz to 13 MHz, so it is good for many different applications. It is compatible with a variety of ultrasound systems, including the GE vivid7 and Logiq e. You can also use the GE 12L-RS wireless transducer with the Logiq e and i systems.
GE also offers many different types of transducer probes. These are designed for use in different clinical settings and offer many benefits. Some models can move across the body’s surface, while others can be inserted through various body openings to get closer to the organ. This helps obtain a more detailed image. This type of probe comes with system controls and is battery operated. GE’s LOGIQ e probe is compatible with the GE vivid7 and is compatible with many other brands.
The NextGen LOGIQ e ultrasound system features a musculoskeletal-specific transducer that can image almost any body part. The software is specifically designed for musculoskeletal medicine and the logging tool helps ensure technical consistency. With a logging tool and fusion, you can track the performance of your device. When the device is updated, you’ll get an updated diagnostic image with fewer complications.
GE i12L-RS probe
The GE i12L-RS Linear Array Ultrasound Probe is a highly versatile linear transducer that is compatible with many GE ultrasound systems. Its multi-selectable fundamental and harmonic frequencies support imaging of peripheral, small, and superficial vascular and musculoskeletal structures. A miniaturized RS connector provides for ease of use. GE offers this probe for sale at a low price through Soma Tech Intl.
If you’re not satisfied with your GE i12L-RS ultrasound probe, don’t worry. Enterprise Ultrasound sells GE ultrasound probes, as well as refurbished and preowned probes. It also offers a probe buyback program, wherein customers can sell their old probes for cash back on GE ultrasound systems. If you need to return an item, contact GE to get a return materials authorization. The returned item must be undamaged and in the original packaging.
GE 4C-RS probe
GE ultrasound transducers can be used with the GE Vivid i, q, or s. The GE i739-RS is a wide-band linear array compatible with the GE Logiq Book XP. GE also makes the t739-RS ultrasound transducer that is compatible with the GE vivid7. These probes have a sector array and convex, curved, or multi-mode doppler.
GE makes many different types of ultrasound transducers and probes, including those without dashes for compatibility with regular ultrasound systems. It also makes portable ultrasound systems and ultra-new machines compatible with GE probes. The GE 4C-RS probe is compatible with a wide range of GE ultrasound machines, including portable versions. With its compatibility with over ten different models, the GE Vivid T8 offers diagnosticians flexibility and allows them to switch between portable and fixed ultrasound machines.