Ultrasound Probe Repair, Model by Model

Diagnose the fault, check whether a repair makes sense, and know exactly what a quote needs — before anything ships. 3,000+ probe references across 43 brands, from GE and Philips to Mindray and Hitachi Aloka.
3,011 probe references  ·  43 brands  ·  691 compatible systems

Find your probe by brand

Every brand hub lists its probe models with per-model fault tables and repair guidance.

GE

370 probe & guide references

Philips

201 probe & guide references

Mindray

205 probe & guide references

Hitachi Aloka

254 probe & guide references

Siemens (Acuson)

195 probe & guide references

Toshiba / Canon

191 probe & guide references

Samsung

156 probe & guide references

Esaote

97 probe & guide references

Sonosite

86 probe & guide references

Samsung Medison

86 probe & guide references

BK Medical

81 probe & guide references

SonoScape

51 probe & guide references

What are you seeing on screen?

Match the symptom, then open your exact model page — each one carries a fault table for that design.

Dark bands or dropout lines

Element or cable-conductor territory. The diagnosis guide separates the two in minutes.

Blurry image cleaning won't fix

Lens wear or early delamination. Rule out the console first, then check the lens.

Bubbles or lifting on the lens

Delamination — usually repairable when caught early, a safety issue when ignored.

Image cuts out when cable moves

Broken internal conductors. The flex test confirms it in minutes.

Cracked housing or strain relief

Mechanical damage that's usually repairable — and worth fixing before fluid gets in.

Failed leak test (endocavity / TEE)

A sealing breach. Stop clinical use and get it assessed.

How a repair assessment works

1 · Identify your model

Find it in the brand hub — the model page lists its known failure modes.

2 · Send the details

Label photo, fault description, console model. The model page tells you exactly what to include.

3 · Written assessment

Whether the fault is repairable and on what terms — confirmed in writing before anything ships.

4 · Repair, exchange or replace

Based on the assessment, not a guess.

Not sure whether repair even makes sense? Read the repair-or-replace decision framework →

Every probe type, from linear to TEE

Linear probes

552 references

Convex probes

458 references

Phased array

314 references

Endocavity

297 references

TEE probes

80 references

Specialty & 3D/4D

176+ references

Biopsy guides: replaced, not repaired

A cracked or worn biopsy guide is a safety issue — geometry decides the needle path, and worn geometry can’t be verified back into tolerance. 1,000+ replacement guide references are listed with per-guide fit checks.

Questions we get asked

Often yes: lens, housing, cable, strain relief and connector damage are routine repairs. Widespread element failure usually is not economical. Each model page on this site lists what typically is and isn’t repairable for that design.

Match the symptom against the fault table on your model’s page, then send the label photo and fault description for a written assessment. Repair-or-replace is decided by damage scope, not by model age alone.

No. This platform does not claim OEM authorization or universal compatibility. Assessments and terms are confirmed in writing per probe.

A photo of the complete model label, a description of the fault (what you see and when it started), the console model, and photos of any physical damage.

No — guides are precision accessories whose safety depends on exact geometry, so they are replaced rather than repaired. Replacement references with fit checks are listed under Biopsy Guides.

Ready for an assessment?

Send the model label, the fault, and the console it runs on. You’ll get a written answer on repairability — not a form response.