INNOFINE JSM-171 Reusable Biopsy Needle Guide for SonoScape 9L-A — Replacement

Replacement reference for the INNOFINE JSM-171 Reusable Biopsy Needle Guide for SonoScape 9L-A: confirm probe fit, guide type and needle gauge before ordering.

Get a Repair Quote for This Model

Send the label photo, fault description and console model — assessment confirmed in writing.

The INNOFINE JSM-171 Reusable Biopsy Needle Guide for SonoScape 9L-A is a positioning accessory, not a repairable device: when a guide is cracked, worn or no longer locks onto the probe, the correct action is replacement. This page helps you confirm the right replacement for your exact probe.

Catalogue name INNOFINE JSM-171 Reusable Biopsy Needle Guide for SonoScape 9L-A
Supplier INNOFINE
Supplier reference JSM-171
Guide type Reusable Biopsy Needle Guide
Compatible probe references SonoScape: 9L-A
Source record INNOFINE product record

Why biopsy guides are replaced rather than repaired

A biopsy guide constrains the needle path relative to the imaging plane. Cracks, deformation or channel wear shift that path, so a damaged guide is a safety issue rather than a repair candidate. Replacement restores the original geometry; repair cannot be verified to.

This reference is listed for the following probe(s): SonoScape: 9L-A. Bracket geometry differs even between visually similar probes, so the pairing above is the starting point – not proof of fit.

When to replace the guide

  • Any crack in the bracket or channel, however small
  • Loose or unreliable locking onto the probe
  • The needle channel is worn, scored or lets the needle wander
  • Warping or distortion after reprocessing
  • Discoloration combined with brittleness of the material

Confirm fit before ordering a replacement

  • Photograph the probe’s full manufacturer and model label and send it with the request.
  • Include photos of the existing guide or bracket and where it clips onto the probe.
  • Quote the reference number printed on the guide or bracket, if legible.
  • Specify the needle gauge range and whether you need a reusable or disposable configuration.
  • Note your sterilization or disinfection workflow so the right configuration is offered.

Similar probe names do not prove that two brackets are interchangeable – the attachment geometry and channel spec decide fit, so compatibility is confirmed against your exact probe label.

Ordering a replacement guide with a probe repair

Ordering a replacement guide alongside a probe repair? Include both in one request with the probe label photo – compatibility for the guide and repairability for the probe get confirmed in a single assessment.

The illustration is representative and is not a photograph of this exact guide. This record does not claim OEM authorization or universal fit. Compatibility, included components, availability and commercial terms are confirmed in writing for the exact probe and guide reference.

WhatsApp Call Email Get a quote