If you’re wondering “Where can I buy a compatible MEDISON SA X6 probe?” then this article will help you make a decision. Although Medison no longer manufactures the model mentioned, you can still find a similar machine, or even a refurbished model, if you’re lucky enough to find one. There are many advantages to using a refurbished model.
SonoAce X6
The SONOACE X6 uses newly developed Digital Beam forming technology. Its design allows it to work in different ultrasound departments. Its exterior consists of various connectors, probe holders, storage compartments, and wheels. In addition, its features make it an ideal choice for a wide range of clinical applications. For more information, read on. Here are some of the features of this ultrasound probe.Medison SA X6 Probe
The SonoAce X6 features a comprehensive range of electronic probes. The FSI (Frequency-Scale Imaging) feature utilizes the entire range of the probe’s frequencies. It incorporates the penetration capability of lower frequencies while maintaining fine pixel uniformity and enhancing Doppler interaction. This innovative design gives physicians more information about patients than ever. Moreover, it offers advanced image processing, including FSI, ensuring superior image quality.
Moreover, the probe uses electrical energy to produce sound. If it is soaked in a solution that is higher than the recommended level, it could malfunction or even burn out. Always make sure to dry the probe thoroughly after use, and to remove any residual coupling gel. If you have any doubts, contact the MEDISON Customer Support Department. Your concern will be addressed immediately. You can also perform short circuit examinations with the probe.
The SONOACE X6 comes with a comprehensive service manual that includes troubleshooting procedures, precautions, and installation instructions. For best results, it should be serviced by a MEDISON Co., Ltd. authorized dealer. If you have any questions, contact their customer care department or an authorized dealer. Its service manual also includes information on electrical safety, electrical hazards, and more.
The SONOACE X6 includes optional software. Some of these include Freehand 3D Pulse wave Doppler, Set-up Options, and DICOM. If you decide to purchase this scanner, you should know that it supports upgrade options. The upgrade process will also include factory settings. During the process, you must restart the SONOACE X6 probe. A new version of the software will take effect.
The PSA interface connects the system and the probe. It contains three 156-Pin Array Probe Connectors and one Static CW Probe Connector. The PSA includes a relay circuit to select a probe. In addition to the four sections, the PSA has additional element selection. The Element Selection circuit uses 16 high voltage switches to select the probes according to the Control Signal output from the FE BD.
The compatible Medison SA X6 SonoAge probe supports the HL5-12ED linear array transducer. The phased array probe has an extended range of frequency (5.0 to 11.0 MHz). The curved array probe has an optional circular shape. It features an adjustable angle, which makes it ideal for use in musculoskeletal ultrasound. In addition, it also includes a free-angle probe.
The parts of the BD SONOACE X6 include BD-349-PSA, BD-349C-PSA-2P, and BD-349-FE. The LCD interface board is BD-349-LCDIF. The AC-DC MODULE SONOACE X4 is AY-342-PWR-DDM. The A260-142A and AY-TB06A-1 are the control panel and speak cable respectively.
SonoAce X6 vs SonoAce R7
If you are comparing the cost and features of two ultrasound probes, you may be wondering which one is better. Both ultrasound probes are high-quality and offer the same features, but one has more powerful capabilities. Medison has developed two ultrasound probes with comparable features. The SonoAce X6 ultrasound system offers a sleek, ergonomic design and advanced imaging functions. Its Full Spectrum Imaging provides high-resolution imaging for a variety of clinical applications, including abdominal, musculoskeletal, cardiovascular, and OB/GYN applications. Its full spectrum imaging technology provides clearer, brighter images that enhance accuracy and efficiency.
The SONOACE X6 includes a service manual for users to download and install updates for their scanner. Its part catalogue lists replacement parts, software versions, and installation instructions. It also includes a NOR Alarm LED and a DICOM file. This manual contains troubleshooting information and can help you determine which one is best for you.
The Samsung SonoAce R7 ultrasound scanner is compatible with both probes. The R7 offers many new features and has more advanced capabilities than the X6. Its ElastoScan feature detects tumors in breast or cervical tissue. The elastoScan imaging helps guide interventional treatments and biopsies. It also features a strain function for diagnosing cardiac dyssynchrony. Its advanced features include the ability to quantify cardiac motion and detect radial speckle tracking.
The SONOACE X6 ultrasound scanner utilizes newly developed Digital Beam forming technology. It is designed to suit the needs of multiple ultrasound departments. Its ultrasonic imaging system is composed of various components such as probe holders, handles, and wheels. These components are highly compatible, so your patients won’t have to switch machines to use it.
Aside from compatibility, the MEDISON SA X6 is also compatible with the SonoAce R7 ultrasound machine. The SA X6 probe is designed for a variety of applications and uses. Its UZI apparata provides high-quality diagnostic images of organs and tissues and helps make accurate diagnoses.
The BD SONOACE X6 uses the same parts as the R7. However, it uses different power parts. The BD-349C-PSA-2P power module is used with the X6. Those parts can be used with both models. However, the BD-349-PSA and BD-349-FE are not compatible with the R7.
In terms of performance and price, the Samsung LF5-13 ultrasound probe is a good value for money. It comes with a 17″ high resolution LCD monitor and powerful Doppler performance. The Philips Epiq 7 offers free-angle probes and the Toshiba PLT-704SBT linear array transducer. Similarly, the Medison SA X6 ultrasound system has a low-profile design and a range of 4.8 to 11.0 MHz.