When it comes to buying a probe, it is important to find one that works well with your specific model of Philips CX50. While the Rev.A model is cheaper than the other revisions, it does have some issues with probe compatibility. The hardware was also prone to bugs, which were fixed in the Rev.B hardware revision. So, if you’re looking for a replacement for your CX50, you’ll want to buy one of the newer versions.
Rev.C
If you are looking for a new TEE transducer, you may want to consider a Philips CX50 X7-2t TEE probe. This transducer offers superior image quality and can image multiple planes at the same time. It even supports 4D imaging. Whether you are comparing images from different planes, or you need more details about structural defects, the Philips CX50 will meet your needs.Philips CX50 Probes
The Philips CX50 has the PureWave crystal technology, which is the latest technology for ultrasound transducers. Its improved imaging quality results in sharper, more detailed, and more intricate images. Philips currently only offers three portable ultrasound machines – the CX30 and CX50 – but they are all worth considering. The CX50 is the most advanced portable ultrasound machine available, offering image enhancing technology and a variety of applications. This machine is also among the most reliable in the market, with a full refund policy only if the probe has a defect.Philips CX50 Probes
The Philips CX50 is a portable ultrasound machine with advanced cardiac imaging features. Its superior image quality and tremendous wall definition make it the perfect machine for shared services. Its advanced features make it a popular choice for larger facilities and is capable of being a stand-alone or shared service system. With a one-year depot warranty and a dedicated cart, the CX50 is the best choice for a busy practice.
Philips has designed its ultrasound systems to meet the needs of the healthcare professional, providing portable and lightweight solutions that achieve reliable results and accuracy. The premium quality of Philips ultrasound probes makes it a perfect choice for any healthcare provider. These ultrasound systems have easy-to-use controls that allow clinicians to steer the probe easily and safely, while being extremely durable and ergonomic. Its patented technology allows physicians to steer the probe easily, making it a versatile tool for any imaging situation.
Rev.C xMATRIX
The Philips CX50 Rev.C ultrasound probe is compatible with the latest xMATRIX technology. The CX50 features a dual-channel imaging system with SonoCT technology to obtain multiple coplanar tomographic images and combine them into one compound image. The CX50 is also equipped with PureWave Crystal technology, a breakthrough single crystal technology that provides greater bandwidth and acoustic efficiency. In addition, the xMATRIX array technology provides 2D imaging with live volume and xPlane imaging.
The Philips CX50 can be used with the iU22 transducer, which offers quantitative measurements of tissue stiffness. In addition to this, the probe also includes the C5-1 probe optimized for liver Shear Wave elastography. This probe uses special ultrasound push pulses to generate detection pulses and calculate shear wave velocities. The iU22 also features QLAB on-board quantification software. It also features the 3DQ and FHN plugins for measuring superficial vessels.
The Philips CX50 is a high-quality ultrasound machine with high-definition transducers. It is capable of using three single-crystal PureWave transducers, C5-1 convex probe, C10-3v endovaginal probe, and S5-1 adult cardiac probe. The single-crystal transducers help improve image quality at deep penetration, which is essential when scanning large patients.
Philips iU22 ultrasound machine also offers Next Generation SonoCT, which allows for multiple coplanar tomographic images to be generated on a single screen. STIC (Spatio-Temporal Image Correlation) automatically acquires a full cardiac cycle and is compatible with QLAB quantification software. The iU22 ultrasound machine also has iSCAN (image optimization) function that optimizes image quality for 2D and 3D modes. The iU22 is compatible with all imaging transducers, including Doppler, XRES, and SonoCT.
QLAB ROI
The Philips CX50 ultrasound probe incorporates the QLAB 3DQ GI tool, which allows users to view and crop 3D image data. Additionally, this tool enables measurement and quantification of the cardiac volume. The QLAB 3DQ GI tool is compatible with the popular QLAB ROI quantification software. Both the QLAB iU22 probe and the Philips CX50 ultrasound probe include Panoramic SonoCT, which is available for both convex and linear transducers.
The CX50 is also equipped with PureWave crystal technology, which improves image quality at higher penetration levels. This makes it easier to diagnose difficult-to-scan patients. Furthermore, the CX50 also comes with Active Native Data, which is an innovative software tool that allows users to analyze images in real time. The probe can also be used in two-dimensional, PW & CW Doppler, and color Doppler modes.
The Philips CX50 Rev.C was released sometime between 2012 and 2013. It is identical to the Rev.A and Rev.B versions, with the exception of the new xMATRIX and the User Interface. The CX50 Rev.C is also compatible with the Philips X7-2t TEE probe, but it does not support the xMATRIX. The CX50 Rev.C is compatible with the Philips CX50 probe.
The Philips CX30 ultrasound probe offers similar performance to the CX50, but is slightly more limited in features. A refurbished CX30 ultrasound probe will have outdated transducer technology and may not support contrast imaging or TEE imaging. Still, this machine offers more than enough features for most ultrasound practitioners. If you’re on a budget, you can opt for a refurbished CX30 ultrasound probe.
iRotate technology
The Philips CX50 X7-2t TEE transducer features iRotate technology, which rotates to provide a view in the acoustical window. This innovative technology allows for the complete stress echo protocol and the acquisition of multiple 2D images. Additionally, the CX50 X7-2t features xMATRIX transducer technology, which enables incremental detail of structural defects.
The Philips CX50 ultrasound machine was introduced in 2008, and quickly established itself as the Gold Standard of portable cardiovascular ultrasound machines. The CX50 continues to update the market with new features and capabilities, making it an excellent choice for shared-service practices. The machine is a high-quality portable ultrasound system that excels in cardiology and gynecology. The Philips CX50 is a highly portable ultrasound machine, allowing it to be easily moved from one department to another. The CX50 is also compact, making it ideal for smaller areas.
The CX50 xMATRIX is easy to use and enables premium image quality. Its special carry case makes it easy to transport to satellite offices and remote locations. The CX50 xMATRIX is compatible with the PureWave transducer technology, which is a breakthrough single crystal technology. This technology enhances the acoustic efficiency of the CX50 probe.
Another advanced feature of the Affiniti 70 is its Fetal Heart Navigator, which allows physicians to acquire a fetal heart volume scan in as little as two seconds. In addition, the Affiniti 70 features QLAB ROI to improve the consistency of acoustic measurements. It also has Active Native Data to facilitate image processing and data re-acquisition. It is compatible with the PW&CW, Color Doppler, and Physio modes.
Single-crystal probes
One of the best features of the Philips CX50 ultrasound is its high-end QLAB software. The QLAB software enables you to expand your patient diagnostic information, including Ultrasound imaging, with advanced apps for GI 3D quantification, Strain Quantification, Live3D (4D TEE), and ICE Intracardiac Echo. The CX50’s PureWave Crystal technology is another great feature. This single crystal technology provides greater acoustic efficiency and bandwidth. It also supports xMATRIX array technology, which allows you to see structures in any direction, including the side of the sector.
If you own a Philips CX50 Rev.B, you can use it with the new version of this ultrasound. This version of the Philips CX50 is almost identical to the Rev.A and Rev.B, but has more powerful hardware and improved imaging. It supports the Philips X7-2t TEE probe. If you are planning to use the Philips X7-2t transesophageal ultrasound probe with your CX50, you can use the CX50 Rev.B. But if you want to use xMATRIX, you must upgrade to a Rev.C.
The CX50 was launched in 2009 as the first portable ultrasound from Philips. It is still the company’s flagship ultrasound machine, incorporating a comprehensive suite of imaging technologies including PureWave single crystal transducers and xMatrix transducers. This ultrasound is an ideal choice for doctors in a range of settings, including emergency care and point of care applications. In addition to the features, this ultrasound is compatible with most ultrasound carts and stands, making it a versatile and useful portable ultrasound machine.
Compared to other portable ultrasound machines, the Philips CX50 is a great investment. It is one of the most expensive portable ultrasound systems on the market, and it includes the latest image enhancing technology. Aside from its image quality, it is also lightweight and portable. The CX50 offers an array of transducers for multiple ultrasound applications, including cardiac, abdominal, and thoracic.