If you’re thinking about purchasing an ultrasound machine, then you should consider the Samsung/Medison MySono U5. This machine is one of the most affordable on the market, and it’s also less expensive than its closest competitor. Plus, Medison has been making 3D/4D ultrasound machines since the mid-late 1990s, so you can rest assured that you’ll get a high-quality machine from this manufacturer.
HM70A replaces MySono U5
The Medison MySono U5 ultrasound machine is a midrange model that offers advanced imaging capabilities. It is now being replaced by the Samsung HM70A portable ultrasound machine, which is a higher-end laptop version. Both ultrasound machines have similar design, intuitive user interface, and automated functions. But one of them is significantly more powerful than the other. So let’s see how these two ultrasounds compare.
The MySono U5 includes various connectors. These are located on the left and right sides of the console. The MySono U5 operates on a lithium-ion battery pack. It uses battery power when the AC adapter is not connected or stable. The MySono U5 also displays a battery-life indication while it is in use. To prevent deterioration, use the HM70A instead.
The MySono U5 features an enhanced processor that can handle up to 128 elements of ultrasound probes. The system also supports Digital Beamforming of TX 32 channels. Its main board implements ultrasound data before the Scan Converter. It is also a PC part, a LAN port, and a USB port. Its software enables it to transmit ultrasound data via a network.
The HM70A features many easy-to-use features. The MySono U5 is only for use by a licensed physician. HM70A has many advantages over the MySono U5. It has more advanced features and capabilities and is priced affordably. It’s comparable to the high-end GE Vivid-i ultrasound. The portable versions of the MySono U5 are the SonoAce R3 and SonoVet R3, which are intended as affordable general imaging and OB/ Vascular units. It replaces the Medison Pico.
The HM70A ultrasound probe features an improved Beamformer Board. Its Beamformer Board delivers high-voltage pulses to the probe and amplifies the echo signal to provide high-quality images. The system supports up to 128 elements of ultrasound probes. The TX Pulser and Receiving Circuit are connected to the Beamformer ASIC. Eight Beamformer ASICs are installed in the Beamformer Board and perform TX Pulser and Digital Beamforming.
CISPR 11 or CISPR 22 compliant
The Samsung Mysono U5 is compliant with CISPR 11 and CISPR 22, and the test method it uses to measure interference in mobile phones and other devices is also based on these standards. The third edition of CISPR 11 was released in 1997, and it replaced the second edition. This edition includes two amendments, one dealing with the classification of equipment and the other addressing measurement uncertainty.
In addition to the test method, CISPR 11 has specified the antenna distance for both group A and group B equipment. During the group A and group B magnetic field measurements, the distance between the antenna and the EUT is 10 meters. Additionally, the standard uses a PK detector for all group A and B equipment. This allows the Samsung Mysono U5 probe to be CISPR 11 or CISPR 22 compliant.
According to CISPR 11, a probe must be able to detect interference from multiple sources in order to be classified as compliant with CISPR 11. Specifically, this standard applies to ISM equipment. This includes information technology equipment, broadcast receiving equipment, and entertainment lighting control equipment. The Samsung Mysono U5 probe is CISPR 11 or CISPR 22 compliant.
The Mysono U5 is a high-resolution color ultrasonographic image scanner that includes a suite of measurement functions. This device incorporates MEDISON’s Digital Beam Forming technology for a variety of ultrasound applications. The system also provides basic measurements as well as application-specific measurement functions. It is a versatile device and is CISPR 11 and CISPR 22 compliant.
Both CISPR 11 and CISPR 22 require the use of the same measuring techniques. The CISPR 25 standard defines the system under test, measurement protocols, and equipment. The device uses 50-O terminations on each AN. This configuration allows for accurate measurements up to 2.5 GHz. The test method is described in detail in CISPR 25 and CISPR 22.
TIb or TIs continuously displayed over the range of 0.0 to maximum output
When using the Samsung Mysono U5, the TIb or TIs continuously displayed on the monitor are a result of the thermal index (MI) and mechanical index (TI). Depending on which mode you choose, one of these will be displayed at all times. The MI will be displayed over the range of 0.0 to 1.9 in increments of 0.1.
In the probe’s LCD, you’ll find three indices, each with a different definition. The default setting will always be the lowest value, but you can change it by changing the sensitivity. You can also increase or decrease the number of focal zones displayed on the monitor. For a high resolution image, you can increase the number of focal zones and the number of frames per second. Lower frame rates and shallower depth will decrease the TI.
The TIb or TIs continuously displayed on the monitor are estimates that take into account the inherent variability of the probe, the range of measurement error, and the presence of fluid, bone, or blood. Non-linear loss and other system controls can also alter the value of the TIb or TIs displayed on the monitor.
The Mysono U5 is intended for use by licensed healthcare practitioners under the supervision of a qualified physician. The probe TIb or TIs continuously displayed over the range of 0.0 to maximum output is certified to comply with the International Electro Technical Commission (IEC). This standard uses symbols to classify connections and warn of possible hazards. The symbols are listed below.
When a probe is connected incorrectly, it is an indication that the DDM or Main Board is malfunctioning. When the probe is not connected properly, it is necessary to call a trained service technician or MEDISON Customer Care Department. The manufacturer of the Samsung Mysono U5 probe is not responsible for any damage caused by incorrect installation or incorrect use of the product.
Depending on the type of instrument, the display may display LMP or GA. In addition, you can customize the font size and color of the display, as well as select a test pattern. The software also has a language selection feature that allows you to enter data from multiple languages. The keyboard also includes buttons for changing the display mode, font size, and auto-unfreeze.
Safety precautions when using a samsung Mysono U5 probe
To avoid electrical shock, the MySono U5 has several safety precautions. First, make sure the probe is inserted into the correct connection. If the connection is made wrong, the probe may experience a short circuit. Also, the probe’s battery pack should not be left in a hot area or near combustible materials. If you notice that the probe is not working properly, contact a technician immediately.
When working with the MySono U5, the user should always use it under the supervision of a licensed physician. It has a series of IEC symbols that classify the connections and warn of potential hazards. You can find the symbols on the probe’s packaging, as well as the MySono U5 Service Manual. Read the label carefully before connecting the probe. Be careful not to immerse the probe in water.