If the CIVCO Disposable Endocavity Needle Guides on your probe is damaged, do not attempt to repair it: guides are precision accessories whose safety depends on exact geometry. This record helps you identify the matching replacement and confirm compatibility.
| Catalogue name | CIVCO Disposable Endocavity Needle Guides |
|---|---|
| Supplier | CIVCO |
| Supplier reference | 610-1144, 610-1145, 610-1274, 610-1275, 610-139, 610-1429, 610-1430, 610-543, 610-588, 610-590, 610-604, 610-605, 610-693, 610-711, 610-842, 610-958, 610-959, 610-987, 610-988, 612-051, 612-061, 613-245, 613-246, 614-079, 614-089, 614-094, 614-110, 614-111, 614-114, 614-115, 639-012, 639-013, 644-068, 644-069, 644-092, 644-093, 644-101, 644-102, 657-014, 657-034, 657-035, 657-067, 657-068, 657-069, 657-070, 667-066, 667-089, 667-090, 667-113, 667-114, 667-117, 667-118, 667-133, 667-134, 674-015, 674-040, 674-050, 676-110, 676-112, 676-132, 676-133, 676-144, 676-150, 676-154, 676-157, 676-167, 676-194, 676-206, 676-225, 677-044, 677-057, 680-113, 680-114, 680-116, 680-117, 680-120, 680-121, 680-130, 680-131, 698-010, 698-011, 698-014, 742-270, 742-306, 742-338, 742-378, 742-379 |
| Guide type | Disposable Biopsy Needle Guide |
| Compatible probe references | Acoustic Imaging: 6.5EF, 6.5EV CLA Alpinion: E3-10 BK Medical: 8554, 8819, E10C4 Canon: 11C3, 11C4, 11CV3, PVF-641VT, PVM-651VT, PVN-661VT, PVQ-641V, PVT-661VT, PVT-681MV, PVT-781VT, PVT-781VTE, PVU-681MVL, PVU-770ST, PVU-781VT, PVU-781VTE Carestream Health: E10C4 Clarius: EC7 ECM: E610P, E610R Esaote: E3-12, E8-5 R10, EC1123, EC123, IVT12, IVT22, SE3123, SE3133, TRT12 Exact Imaging: EV9C Fujifilm: C41V1, CC41R, CC41R1, CC41R2, EUP-CC531, EUP-V53W, UST-670P-5, UST-675P, UST-676P, UST-677P, UST-678, UST-981-5, UST-984-5 GE: BE9C, BE9CS, E72, E721, E8C, E8C-RS, E8CS, ECLA7.0MI, IC5-9-D, IC5-9H, IC5-9W-RS, IC9, IC9B-RS, RIC10, RIC5-9-D, RIC5-9W-RS, RIC6-12-D Hitachi: C41V, UST-676LP, UST-679, UST-9112-5, UST-945(B)P-5, UST-945B-5, UST-952(DP)-5, UST-952-5, UST-977-5 Mindray: 65EB10EA, 6CV1, 6CV1s, EV6.5MHz/R10, V10-4, V10-4s, V11-3s, V11-3Ws Philips: 3D9-3v, BP10-5ec, C10-3v, C10-4ec, C8-4v, C9-3v, C9-4ec, C9-4v, C9-5 ICT, C9-5ec, E6509, E6514, E7511, S4-1 Pie Medical: 5.017.5SR10, C7-4R8 TRD Medison: BCC4-9, E3-12A, EA2-11AR, EA2-11AV, EA2-11B, EC4-9ES, EC4-9IS, ER4-9/10ED, ER4-9ES, EV3-10B, EV4-9/10ED, EVN4-9, NER4-9ES, NEV4-9ES, V5-9, VR5-9 Shimadzu: UB10R-065U Siemens: 10EV3, 10MC3, 6.5EC10, 9EC4, 9MC3, 9VE4, BE9-4, BP10-3, BP9-4, EC10C5, EC7, EC9-4, EC9-4W, EV-8C4, EV9-4, MC9-4 SonoSite: C8, IC10-3 SuperSonic Imagine: E12-3, SE12-3, SEV12-3 Terason: 10EC4, 8EC4V Ultrasonix: EC9-5 |
| Source record | CIVCO product record |
Why biopsy guides are replaced rather than repaired
Guides take repeated mounting, sterilization and needle passes. Wear accumulates in the attachment points and needle channel, and there is no economical way to re-machine a worn guide back into tolerance. Replacement is the standard practice.
This reference is listed for the following probe(s): Acoustic Imaging: 6.5EF, 6.5EV CLA Alpinion: E3-10 BK Medical: 8554, 8819, E10C4 Canon: 11C3, 11C4, 11CV3, PVF-641VT, PVM-651VT, PVN-661VT, PVQ-641V, PVT-661VT, PVT-681MV, PVT-781VT, PVT-781VTE, PVU-681MVL, PVU-770ST, PVU-781VT, PVU-781VTE Carestream Health: E10C4 Clarius: EC7 ECM: E610P, E610R Esaote: E3-12, E8-5 R10, EC1123, EC123, IVT12, IVT22, SE3123, SE3133, TRT12 Exact Imaging: EV9C Fujifilm: C41V1, CC41R, CC41R1, CC41R2, EUP-CC531, EUP-V53W, UST-670P-5, UST-675P, UST-676P, UST-677P, UST-678, UST-981-5, UST-984-5 GE: BE9C, BE9CS, E72, E721, E8C, E8C-RS, E8CS, ECLA7.0MI, IC5-9-D, IC5-9H, IC5-9W-RS, IC9, IC9B-RS, RIC10, RIC5-9-D, RIC5-9W-RS, RIC6-12-D Hitachi: C41V, UST-676LP, UST-679, UST-9112-5, UST-945(B)P-5, UST-945B-5, UST-952(DP)-5, UST-952-5, UST-977-5 Mindray: 65EB10EA, 6CV1, 6CV1s, EV6.5MHz/R10, V10-4, V10-4s, V11-3s, V11-3Ws Philips: 3D9-3v, BP10-5ec, C10-3v, C10-4ec, C8-4v, C9-3v, C9-4ec, C9-4v, C9-5 ICT, C9-5ec, E6509, E6514, E7511, S4-1 Pie Medical: 5.017.5SR10, C7-4R8 TRD Medison: BCC4-9, E3-12A, EA2-11AR, EA2-11AV, EA2-11B, EC4-9ES, EC4-9IS, ER4-9/10ED, ER4-9ES, EV3-10B, EV4-9/10ED, EVN4-9, NER4-9ES, NEV4-9ES, V5-9, VR5-9 Shimadzu: UB10R-065U Siemens: 10EV3, 10MC3, 6.5EC10, 9EC4, 9MC3, 9VE4, BE9-4, BP10-3, BP9-4, EC10C5, EC7, EC9-4, EC9-4W, EV-8C4, EV9-4, MC9-4 SonoSite: C8, IC10-3 SuperSonic Imagine: E12-3, SE12-3, SEV12-3 Terason: 10EC4, 8EC4V Ultrasonix: EC9-5. Bracket geometry differs even between visually similar probes, so the pairing above is the starting point – not proof of fit.
When to replace the guide
- Visible cracks anywhere on the bracket or needle channel
- Loose or unreliable locking onto the probe
- The needle channel is worn, scored or lets the needle wander
- Deformation after autoclaving or disinfection
- Discoloration combined with brittleness of the material
Confirm fit before ordering a replacement
- Send a clear photograph of the complete probe manufacturer and model label.
- Include photos of the existing guide or bracket and where it clips onto the probe.
- Quote the reference number printed on the guide or bracket, if legible.
- Specify the needle gauge range and whether you need a reusable or disposable configuration.
- Note your sterilization or disinfection workflow so the right configuration is offered.
Similar probe names do not prove that two brackets are interchangeable – the attachment geometry and channel spec decide fit, so compatibility is confirmed against your exact probe label.
Ordering a replacement guide with a probe repair
Ordering a replacement guide alongside a probe repair? Include both in one request with the probe label photo – compatibility for the guide and repairability for the probe get confirmed in a single assessment.
The illustration is representative and is not a photograph of this exact guide. This record does not claim OEM authorization or universal fit. Compatibility, included components, availability and commercial terms are confirmed in writing for the exact probe and guide reference.






Reviews
There are no reviews yet.