Biopsy guides like the CIVCO Infiniti Plus Disposable Needle Guide Replacement Kits are replaced rather than repaired – the bracket geometry and needle channel must stay within tolerance, and a worn or damaged guide should come out of service. Use this page to confirm fit before ordering a replacement.
| Catalogue name | CIVCO Infiniti Plus Disposable Needle Guide Replacement Kits |
|---|---|
| Supplier | CIVCO |
| Supplier reference | 610-1214, 610-1215, 610-1231, 610-1232, 610-1235, 610-1236, 610-2340, 610-2341, 610-2345, 610-2346 |
| Guide type | Needle Guide Replacement Kit |
| Compatible probe references | Siemens Freestyle Ultrasound System ; Sterile Infiniti |
| Source record | CIVCO product record |
Why biopsy guides are replaced rather than repaired
Unlike the probe itself – where lenses, cables and connectors are routinely rebuilt – a guide is a single precision part. Once its bracket or channel is worn or cracked, tolerances are gone and the guide should be replaced, not patched.
This reference is listed for the following probe(s): Siemens Freestyle Ultrasound System ; Sterile Infiniti. Bracket geometry differs even between visually similar probes, so the pairing above is the starting point – not proof of fit.
When to replace the guide
- Any crack in the bracket or channel, however small
- Loose or unreliable locking onto the probe
- The needle channel is worn, scored or lets the needle wander
- Warping or distortion after reprocessing
- Discoloration combined with brittleness of the material
Confirm fit before ordering a replacement
- Send a clear photograph of the complete probe manufacturer and model label.
- Include photos of the existing guide or bracket and where it clips onto the probe.
- State the guide or bracket reference if it is printed on the part.
- State the needle gauges you work with and whether reusable or disposable is required.
- Confirm sterilization or disinfection requirements in the request.
Similar probe names do not prove that two brackets are interchangeable – the attachment geometry and channel spec decide fit, so compatibility is confirmed against your exact probe label.
Ordering a replacement guide with a probe repair
Ordering a replacement guide alongside a probe repair? Include both in one request with the probe label photo – compatibility for the guide and repairability for the probe get confirmed in a single assessment.
The illustration is representative and is not a photograph of this exact guide. This record does not claim OEM authorization or universal fit. Compatibility, included components, availability and commercial terms are confirmed in writing for the exact probe and guide reference.






Reviews
There are no reviews yet.