INNOFINE JSM-068 Reusable Biopsy Needle Guide for Canon PLT-805AT / PLT-1005BT / PLU-1005BT — Replacement

Replacement reference for the INNOFINE JSM-068 Reusable Biopsy Needle Guide for Canon PLT-805AT / PLT-1005BT / PLU-1005BT: confirm probe fit, guide type and needle gauge before ordering.

Get a Repair Quote for This Model

Send the label photo, fault description and console model — assessment confirmed in writing.

If the INNOFINE JSM-068 Reusable Biopsy Needle Guide for Canon PLT-805AT / PLT-1005BT / PLU-1005BT on your probe is damaged, do not attempt to repair it: guides are precision accessories whose safety depends on exact geometry. This record helps you identify the matching replacement and confirm compatibility.

Catalogue name INNOFINE JSM-068 Reusable Biopsy Needle Guide for Canon PLT-805AT / PLT-1005BT / PLU-1005BT
Supplier INNOFINE
Supplier reference JSM-068
Guide type Reusable Biopsy Needle Guide
Compatible probe references Canon: PLT-805AT, PLT-1005BT, PLU-1005BT
Source record INNOFINE product record

Why biopsy guides are replaced rather than repaired

Guides take repeated mounting, sterilization and needle passes. Wear accumulates in the attachment points and needle channel, and there is no economical way to re-machine a worn guide back into tolerance. Replacement is the standard practice.

This reference is listed for the following probe(s): Canon: PLT-805AT, PLT-1005BT, PLU-1005BT. Bracket geometry differs even between visually similar probes, so the pairing above is the starting point – not proof of fit.

When to replace the guide

  • Visible cracks anywhere on the bracket or needle channel
  • Loose or unreliable locking onto the probe
  • The needle channel is worn, scored or lets the needle wander
  • Deformation after autoclaving or disinfection
  • Brittle, discolored material that flexes differently than new

Confirm fit before ordering a replacement

  • Photograph the probe’s full manufacturer and model label and send it with the request.
  • Photograph the current guide or bracket, including the attachment point on the probe.
  • Quote the reference number printed on the guide or bracket, if legible.
  • Specify the needle gauge range and whether you need a reusable or disposable configuration.
  • Confirm sterilization or disinfection requirements in the request.

Similar probe names do not prove that two brackets are interchangeable – the attachment geometry and channel spec decide fit, so compatibility is confirmed against your exact probe label.

Ordering a replacement guide with a probe repair

Ordering a replacement guide alongside a probe repair? Include both in one request with the probe label photo – compatibility for the guide and repairability for the probe get confirmed in a single assessment.

The illustration is representative and is not a photograph of this exact guide. This record does not claim OEM authorization or universal fit. Compatibility, included components, availability and commercial terms are confirmed in writing for the exact probe and guide reference.

Reviews

There are no reviews yet.

Be the first to review “INNOFINE JSM-068 Reusable Biopsy Needle Guide for Canon PLT-805AT / PLT-1005BT / PLU-1005BT — Replacement”

Your email address will not be published. Required fields are marked *