Leapmed 10610802 Disposable Biopsy Needle Guide for Mindray L12-4S / L12-3E / 7L4A +2 — Replacement

Replacement reference for the Leapmed 10610802 Disposable Biopsy Needle Guide for Mindray L12-4S / L12-3E / 7L4A +2: confirm probe fit, guide type and needle gauge before ordering.

Get a Repair Quote for This Model

Send the label photo, fault description and console model — assessment confirmed in writing.

The Leapmed 10610802 Disposable Biopsy Needle Guide for Mindray L12-4S / L12-3E / 7L4A +2 is a positioning accessory, not a repairable device: when a guide is cracked, worn or no longer locks onto the probe, the correct action is replacement. This page helps you confirm the right replacement for your exact probe.

Catalogue name Leapmed 10610802 Disposable Biopsy Needle Guide for Mindray L12-4S / L12-3E / 7L4A +2
Supplier Leapmed
Supplier reference 10610802, 10610902
Guide type Disposable Biopsy Needle Guide
Compatible probe references Mindray: L12-4S, L12-3E, 7L4A, 7L4, L14-6NS
Source record Leapmed product record

Why biopsy guides are replaced rather than repaired

Guides take repeated mounting, sterilization and needle passes. Wear accumulates in the attachment points and needle channel, and there is no economical way to re-machine a worn guide back into tolerance. Replacement is the standard practice.

This reference is listed for the following probe(s): Mindray: L12-4S, L12-3E, 7L4A, 7L4, L14-6NS. Bracket geometry differs even between visually similar probes, so the pairing above is the starting point – not proof of fit.

When to replace the guide

  • Any crack in the bracket or channel, however small
  • Loose or unreliable locking onto the probe
  • The needle channel is worn, scored or lets the needle wander
  • Warping or distortion after reprocessing
  • Brittle, discolored material that flexes differently than new

Confirm fit before ordering a replacement

  • Photograph the probe’s full manufacturer and model label and send it with the request.
  • Include photos of the existing guide or bracket and where it clips onto the probe.
  • Quote the reference number printed on the guide or bracket, if legible.
  • State the needle gauges you work with and whether reusable or disposable is required.
  • Confirm sterilization or disinfection requirements in the request.

Similar probe names do not prove that two brackets are interchangeable – the attachment geometry and channel spec decide fit, so compatibility is confirmed against your exact probe label.

Ordering a replacement guide with a probe repair

If the probe itself is also damaged, mention it in the same request – a probe repair and a replacement guide can be assessed and quoted together, which is usually faster than handling them separately.

The illustration is representative and is not a photograph of this exact guide. This record does not claim OEM authorization or universal fit. Compatibility, included components, availability and commercial terms are confirmed in writing for the exact probe and guide reference.

Reviews

There are no reviews yet.

Be the first to review “Leapmed 10610802 Disposable Biopsy Needle Guide for Mindray L12-4S / L12-3E / 7L4A +2 — Replacement”

Your email address will not be published. Required fields are marked *