Leapmed 120102 Reusable Biopsy Needle Guide for Philips L12-3 — Replacement

Replacement reference for the Leapmed 120102 Reusable Biopsy Needle Guide for Philips L12-3: confirm probe fit, guide type and needle gauge before ordering.

Get a Repair Quote for This Model

Send the label photo, fault description and console model — assessment confirmed in writing.

The Leapmed 120102 Reusable Biopsy Needle Guide for Philips L12-3 is a positioning accessory, not a repairable device: when a guide is cracked, worn or no longer locks onto the probe, the correct action is replacement. This page helps you confirm the right replacement for your exact probe.

Catalogue name Leapmed 120102 Reusable Biopsy Needle Guide for Philips L12-3
Guide supplier Leapmed
Supplier reference 120102
Guide type Reusable Biopsy Needle Guide
Compatible probe references Philips: L12-3
Source record Supplier product record

Why biopsy guides are replaced rather than repaired

Unlike the probe itself – where lenses, cables and connectors are routinely rebuilt – a guide is a single precision part. Once its bracket or channel is worn or cracked, tolerances are gone and the guide should be replaced, not patched.

This reference is listed for the following probe(s): Philips: L12-3. Bracket geometry differs even between visually similar probes, so the pairing above is the starting point – not proof of fit.

When to replace the guide

  • Visible cracks anywhere on the bracket or needle channel
  • The guide no longer clicks or locks firmly onto the probe
  • A worn or scored channel that no longer tracks the needle cleanly
  • Deformation after autoclaving or disinfection
  • Discoloration combined with brittleness of the material

Confirm fit before ordering a replacement

  • Photograph the probe’s full manufacturer and model label and send it with the request.
  • Photograph the current guide or bracket, including the attachment point on the probe.
  • Quote the reference number printed on the guide or bracket, if legible.
  • State the needle gauges you work with and whether reusable or disposable is required.
  • Note your sterilization or disinfection workflow so the right configuration is offered.

Similar probe names do not prove that two brackets are interchangeable – the attachment geometry and channel spec decide fit, so compatibility is confirmed against your exact probe label.

Ordering a replacement guide with a probe repair

Ordering a replacement guide alongside a probe repair? Include both in one request with the probe label photo – compatibility for the guide and repairability for the probe get confirmed in a single assessment.

The illustration is representative and is not a photograph of this exact guide. This record does not claim OEM authorization or universal fit. Compatibility, included components, availability and commercial terms are confirmed in writing for the exact probe and guide reference.

Reviews

There are no reviews yet.

Be the first to review “Leapmed 120102 Reusable Biopsy Needle Guide for Philips L12-3 — Replacement”

Your email address will not be published. Required fields are marked *