CIVCO Reusable General Purpose Ultrasound Needle Guide — Replacement

Replacement reference for the CIVCO Reusable General Purpose Ultrasound Needle Guide: confirm probe fit, guide type and needle gauge before ordering.

Get a Repair Quote for This Model

Send the label photo, fault description and console model — assessment confirmed in writing.

The CIVCO Reusable General Purpose Ultrasound Needle Guide is a positioning accessory, not a repairable device: when a guide is cracked, worn or no longer locks onto the probe, the correct action is replacement. This page helps you confirm the right replacement for your exact probe.

Catalogue name CIVCO Reusable General Purpose Ultrasound Needle Guide
Supplier CIVCO
Supplier reference 639-053, 639-054, 667-095, 667-097, 667-099, 667-119, 667-139
Guide type Reusable Biopsy Needle Guide
Compatible probe references Esaote: C1-8, L4-15, LA533, SL1543 GE: C2-7 Philips: C5-2, C8-5, C9-2, S4-2, S5-1, S5-2
Source record CIVCO product record

Why biopsy guides are replaced rather than repaired

Unlike the probe itself – where lenses, cables and connectors are routinely rebuilt – a guide is a single precision part. Once its bracket or channel is worn or cracked, tolerances are gone and the guide should be replaced, not patched.

This reference is listed for the following probe(s): Esaote: C1-8, L4-15, LA533, SL1543 GE: C2-7 Philips: C5-2, C8-5, C9-2, S4-2, S5-1, S5-2. Bracket geometry differs even between visually similar probes, so the pairing above is the starting point – not proof of fit.

When to replace the guide

  • Visible cracks anywhere on the bracket or needle channel
  • The guide no longer clicks or locks firmly onto the probe
  • A worn or scored channel that no longer tracks the needle cleanly
  • Warping or distortion after reprocessing
  • Discoloration combined with brittleness of the material

Confirm fit before ordering a replacement

  • Send a clear photograph of the complete probe manufacturer and model label.
  • Include photos of the existing guide or bracket and where it clips onto the probe.
  • State the guide or bracket reference if it is printed on the part.
  • Specify the needle gauge range and whether you need a reusable or disposable configuration.
  • Note your sterilization or disinfection workflow so the right configuration is offered.

Similar probe names do not prove that two brackets are interchangeable – the attachment geometry and channel spec decide fit, so compatibility is confirmed against your exact probe label.

Ordering a replacement guide with a probe repair

If the probe itself is also damaged, mention it in the same request – a probe repair and a replacement guide can be assessed and quoted together, which is usually faster than handling them separately.

The illustration is representative and is not a photograph of this exact guide. This record does not claim OEM authorization or universal fit. Compatibility, included components, availability and commercial terms are confirmed in writing for the exact probe and guide reference.