CIVCO Ultra-Pro 3 Disposable Replacement Kits — Replacement

Replacement reference for the CIVCO Ultra-Pro 3 Disposable Replacement Kits: confirm probe fit, guide type and needle gauge before ordering.

Get a Repair Quote for This Model

Send the label photo, fault description and console model — assessment confirmed in writing.

The CIVCO Ultra-Pro 3 Disposable Replacement Kits is a positioning accessory, not a repairable device: when a guide is cracked, worn or no longer locks onto the probe, the correct action is replacement. This page helps you confirm the right replacement for your exact probe.

Catalogue name CIVCO Ultra-Pro 3 Disposable Replacement Kits
Supplier CIVCO
Supplier reference 610-901, 610-918, 610-919
Guide type Needle Guide Replacement Kit
Compatible probe references Ultra-Pro II or Ultra-Pro transducer brackets
Source record CIVCO product record

Why biopsy guides are replaced rather than repaired

A biopsy guide constrains the needle path relative to the imaging plane. Cracks, deformation or channel wear shift that path, so a damaged guide is a safety issue rather than a repair candidate. Replacement restores the original geometry; repair cannot be verified to.

This reference is listed for the following probe(s): Ultra-Pro II or Ultra-Pro transducer brackets. Bracket geometry differs even between visually similar probes, so the pairing above is the starting point – not proof of fit.

When to replace the guide

  • Visible cracks anywhere on the bracket or needle channel
  • Loose or unreliable locking onto the probe
  • The needle channel is worn, scored or lets the needle wander
  • Warping or distortion after reprocessing
  • Discoloration combined with brittleness of the material

Confirm fit before ordering a replacement

  • Send a clear photograph of the complete probe manufacturer and model label.
  • Photograph the current guide or bracket, including the attachment point on the probe.
  • State the guide or bracket reference if it is printed on the part.
  • Specify the needle gauge range and whether you need a reusable or disposable configuration.
  • Confirm sterilization or disinfection requirements in the request.

Similar probe names do not prove that two brackets are interchangeable – the attachment geometry and channel spec decide fit, so compatibility is confirmed against your exact probe label.

Ordering a replacement guide with a probe repair

Ordering a replacement guide alongside a probe repair? Include both in one request with the probe label photo – compatibility for the guide and repairability for the probe get confirmed in a single assessment.