INNOFINE DE-001 Disposable Biopsy Needle Guide for Samsung EC4-9IS / EC4-9ES / ER4-9ES — Replacement

Replacement reference for the INNOFINE DE-001 Disposable Biopsy Needle Guide for Samsung EC4-9IS / EC4-9ES / ER4-9ES: confirm probe fit, guide type and needle gauge before ordering.

Get a Repair Quote for This Model

Send the label photo, fault description and console model — assessment confirmed in writing.

The INNOFINE DE-001 Disposable Biopsy Needle Guide for Samsung EC4-9IS / EC4-9ES / ER4-9ES is a positioning accessory, not a repairable device: when a guide is cracked, worn or no longer locks onto the probe, the correct action is replacement. This page helps you confirm the right replacement for your exact probe.

Catalogue name INNOFINE DE-001 Disposable Biopsy Needle Guide for Samsung EC4-9IS / EC4-9ES / ER4-9ES
Supplier INNOFINE
Supplier reference DE-001
Guide type Disposable Biopsy Needle Guide
Compatible probe references Samsung: EC4-9IS, EC4-9ES, ER4-9ES
Source record INNOFINE product record

Why biopsy guides are replaced rather than repaired

A biopsy guide constrains the needle path relative to the imaging plane. Cracks, deformation or channel wear shift that path, so a damaged guide is a safety issue rather than a repair candidate. Replacement restores the original geometry; repair cannot be verified to.

This reference is listed for the following probe(s): Samsung: EC4-9IS, EC4-9ES, ER4-9ES. Bracket geometry differs even between visually similar probes, so the pairing above is the starting point – not proof of fit.

When to replace the guide

  • Any crack in the bracket or channel, however small
  • The guide no longer clicks or locks firmly onto the probe
  • The needle channel is worn, scored or lets the needle wander
  • Deformation after autoclaving or disinfection
  • Brittle, discolored material that flexes differently than new

Confirm fit before ordering a replacement

  • Send a clear photograph of the complete probe manufacturer and model label.
  • Include photos of the existing guide or bracket and where it clips onto the probe.
  • Quote the reference number printed on the guide or bracket, if legible.
  • Specify the needle gauge range and whether you need a reusable or disposable configuration.
  • Note your sterilization or disinfection workflow so the right configuration is offered.

Similar probe names do not prove that two brackets are interchangeable – the attachment geometry and channel spec decide fit, so compatibility is confirmed against your exact probe label.

Ordering a replacement guide with a probe repair

If the probe itself is also damaged, mention it in the same request – a probe repair and a replacement guide can be assessed and quoted together, which is usually faster than handling them separately.

The illustration is representative and is not a photograph of this exact guide. This record does not claim OEM authorization or universal fit. Compatibility, included components, availability and commercial terms are confirmed in writing for the exact probe and guide reference.

WhatsApp Call Email Get a quote