INNOFINE JEM-019 Reusable Biopsy Needle Guide for Canon PVT-781VT / PVU-781VT / PVT-781VTE +1 — Replacement

Replacement reference for the INNOFINE JEM-019 Reusable Biopsy Needle Guide for Canon PVT-781VT / PVU-781VT / PVT-781VTE +1: confirm probe fit, guide type and needle gauge before ordering.

Get a Repair Quote for This Model

Send the label photo, fault description and console model — assessment confirmed in writing.

Model reference
INNOFINE JEM-019 Reusable Biopsy Needle Guide for Canon PVT-781VT / PVU-781VT / PVT-781VTE +1 — Replacement
Manufacturer
INNOFINE
Pre-screening
Written feasibility check from screen & label photos before shipping
In-house time
~5–7 working days (Shenzhen bench)
Return logistics
Free return freight & customs duties worldwide — even if unrepairable
Warranty
6–12 months written · tested on live OEM ultrasound host

Biopsy guides like the INNOFINE JEM-019 Reusable Biopsy Needle Guide for Canon PVT-781VT / PVU-781VT / PVT-781VTE +1 are replaced rather than repaired – the bracket geometry and needle channel must stay within tolerance, and a worn or damaged guide should come out of service. Use this page to confirm fit before ordering a replacement.

Catalogue name INNOFINE JEM-019 Reusable Biopsy Needle Guide for Canon PVT-781VT / PVU-781VT / PVT-781VTE +1
Supplier INNOFINE
Supplier reference JEM-019
Guide type Reusable Biopsy Needle Guide
Compatible probe references Canon: PVT-781VT, PVU-781VT, PVT-781VTE, PVU-781VTE
Source record INNOFINE product record

Why biopsy guides are replaced rather than repaired

A biopsy guide constrains the needle path relative to the imaging plane. Cracks, deformation or channel wear shift that path, so a damaged guide is a safety issue rather than a repair candidate. Replacement restores the original geometry; repair cannot be verified to.

This reference is listed for the following probe(s): Canon: PVT-781VT, PVU-781VT, PVT-781VTE, PVU-781VTE. Bracket geometry differs even between visually similar probes, so the pairing above is the starting point – not proof of fit.

When to replace the guide

  • Any crack in the bracket or channel, however small
  • The guide no longer clicks or locks firmly onto the probe
  • The needle channel is worn, scored or lets the needle wander
  • Warping or distortion after reprocessing
  • Discoloration combined with brittleness of the material

Confirm fit before ordering a replacement

  • Send a clear photograph of the complete probe manufacturer and model label.
  • Include photos of the existing guide or bracket and where it clips onto the probe.
  • Quote the reference number printed on the guide or bracket, if legible.
  • Specify the needle gauge range and whether you need a reusable or disposable configuration.
  • Confirm sterilization or disinfection requirements in the request.

Similar probe names do not prove that two brackets are interchangeable – the attachment geometry and channel spec decide fit, so compatibility is confirmed against your exact probe label.

Ordering a replacement guide with a probe repair

Ordering a replacement guide alongside a probe repair? Include both in one request with the probe label photo – compatibility for the guide and repairability for the probe get confirmed in a single assessment.

The illustration is representative and is not a photograph of this exact guide. This record does not claim OEM authorization or universal fit. Compatibility, included components, availability and commercial terms are confirmed in writing for the exact probe and guide reference.

WhatsApp Request Assessment