If the INNOFINE JSM-024 Reusable Biopsy Needle Guide for Mindray C6-2GE / C6-2Gs / C6-2GU on your probe is damaged, do not attempt to repair it: guides are precision accessories whose safety depends on exact geometry. This record helps you identify the matching replacement and confirm compatibility.
| Catalogue name | INNOFINE JSM-024 Reusable Biopsy Needle Guide for Mindray C6-2GE / C6-2Gs / C6-2GU |
|---|---|
| Supplier | INNOFINE |
| Supplier reference | JSM-024 |
| Guide type | Reusable Biopsy Needle Guide |
| Compatible probe references | Mindray: C6-2GE, C6-2Gs, C6-2GU |
| Source record | INNOFINE product record |
Why biopsy guides are replaced rather than repaired
Guides take repeated mounting, sterilization and needle passes. Wear accumulates in the attachment points and needle channel, and there is no economical way to re-machine a worn guide back into tolerance. Replacement is the standard practice.
This reference is listed for the following probe(s): Mindray: C6-2GE, C6-2Gs, C6-2GU. Bracket geometry differs even between visually similar probes, so the pairing above is the starting point – not proof of fit.
When to replace the guide
- Visible cracks anywhere on the bracket or needle channel
- The guide no longer clicks or locks firmly onto the probe
- The needle channel is worn, scored or lets the needle wander
- Deformation after autoclaving or disinfection
- Brittle, discolored material that flexes differently than new
Confirm fit before ordering a replacement
- Send a clear photograph of the complete probe manufacturer and model label.
- Include photos of the existing guide or bracket and where it clips onto the probe.
- Quote the reference number printed on the guide or bracket, if legible.
- Specify the needle gauge range and whether you need a reusable or disposable configuration.
- Confirm sterilization or disinfection requirements in the request.
Similar probe names do not prove that two brackets are interchangeable – the attachment geometry and channel spec decide fit, so compatibility is confirmed against your exact probe label.
Ordering a replacement guide with a probe repair
If the probe itself is also damaged, mention it in the same request – a probe repair and a replacement guide can be assessed and quoted together, which is usually faster than handling them separately.
The illustration is representative and is not a photograph of this exact guide. This record does not claim OEM authorization or universal fit. Compatibility, included components, availability and commercial terms are confirmed in writing for the exact probe and guide reference.





