Landwind 35C60H Ultrasound Probe Repair
Fault diagnosis and repair options for the Landwind 35C60H: failure modes, self-checks and what an assessment needs.
Table of Contents
PRODUCT DETAILS
Supply Ability
Supply Ability 5000 Unit/Units per Year
Packaging & Delivery
| Packaging Details | Common Box |
| Port | Hongkong |
| Picture Example: | ![]() ![]() |
DESCRIPTION
A failing Landwind 35C60H does not always mean buying a new probe. Use the fault table below to match what you are seeing on screen to a likely cause, then check what a repair assessment would need.
| Manufacturer | Landwind |
|---|---|
| Model | 35C60H |
Common failure modes for the 35C60H
Match what you are seeing against the table below. The right-hand column reflects how faults of this kind typically assess – the actual verdict always depends on the individual probe.
| What you see | Likely cause | Typically repairable? |
|---|---|---|
| Dark bands or dropout lines in the image | Element dropout, or a conductor break inside the cable | Case by case |
| Visible nicks, grooves or staining on the lens surface | Wear from use, or chemical attack from disinfectants | Usually repairable |
| Latch or locking hardware damaged on the connector shell | Mechanical damage to the connector shell | Usually repairable |
| Depth performance clearly below what this probe used to deliver | Ageing elements or lens delamination reducing acoustic output | Case by case |
| Split seams or impact marks on the probe body | A drop or knock; housings are routinely replaced or resealed | Usually repairable |
| Large areas of the array not firing | Widespread element or acoustic stack failure | Usually not economical |
| Image cuts out when the cable is flexed | One or more conductors broken inside the cable bundle | Case by case |
Check these before you ship the probe
- Photograph the complete manufacturer label – the exact revision matters for parts compatibility.
- Compare penetration and uniformity against a known-good probe on the same preset.
- Run the system’s built-in probe test or element check if your console provides one.
- Examine the connector for bent or corroded pins, cracks and a working locking mechanism.
- Check the strain reliefs at both ends for splits, stiffness or separation from the cable.
Repair, exchange or replace — which applies to your 35C60H
For the 35C60H, think in terms of damage depth: surface and cable-level faults are usually repairable at a fraction of replacement cost; acoustic stack failures are evaluated case by case; extensive element loss generally means replacement. Send the symptoms and photos first – that determines the path before anything ships.
What we need to quote your 35C60H repair
- A clear photo of the complete manufacturer and model label on the probe
- A description of the fault: what you see on screen and when it started
- The ultrasound system (console) the probe is used with
- Screenshots or photos of the image problem, if the fault is visual
- Photos of any physical damage – lens, housing, cable or connector
Images shown are representative and are not photographs of an individual unit. Nothing on this page claims OEM authorization or guarantees universal fit. Whether a specific 35C60H can be repaired, and on what terms, is confirmed in writing once the probe has been assessed.
Company Profile



Sample Room

Customer Feedbacks




Exhibition




Production Process





Packing & Shipping




FAQ
Q: What is the MOQ?
A: 1pc.
Q: How about your delivery time?
A: 1~15 days depends on your order quantity.
Q: What is your terms of delivery?
A: DHL,TNT, EMS,UPS,FedEx,also can use customer’s freight forwarder.
Q: What is your terms of payment?
A: Western union, Alibaba Trade Assurance, T/T in advance.
Q: Do you test all your goods before delivery?
A: Yes, we have 100% tested our goods before delivery.
Q: What is your Service & Return policy?
A: If the probe is not compatible with your machine or there are any quality problem within 7 days after receiving the goods, please feel free to contact us. We will send a replacement probe or refund the payment to you.