Leapmed 10202002 Disposable Biopsy Needle Guide for Mindray L12-3E / L12-4S / 7L4A +1 — Replacement

Replacement reference for the Leapmed 10202002 Disposable Biopsy Needle Guide for Mindray L12-3E / L12-4S / 7L4A +1: confirm probe fit, guide type and needle gauge before ordering.

Get a Repair Quote for This Model

Send the label photo, fault description and console model — assessment confirmed in writing.

If the Leapmed 10202002 Disposable Biopsy Needle Guide for Mindray L12-3E / L12-4S / 7L4A +1 on your probe is damaged, do not attempt to repair it: guides are precision accessories whose safety depends on exact geometry. This record helps you identify the matching replacement and confirm compatibility.

Catalogue name Leapmed 10202002 Disposable Biopsy Needle Guide for Mindray L12-3E / L12-4S / 7L4A +1
Supplier Leapmed
Supplier reference 10202002, 10602002
Guide type Disposable Biopsy Needle Guide
Compatible probe references Mindray: L12-3E, L12-4S, 7L4A, 7L4
Source record Leapmed product record

Why biopsy guides are replaced rather than repaired

A biopsy guide constrains the needle path relative to the imaging plane. Cracks, deformation or channel wear shift that path, so a damaged guide is a safety issue rather than a repair candidate. Replacement restores the original geometry; repair cannot be verified to.

This reference is listed for the following probe(s): Mindray: L12-3E, L12-4S, 7L4A, 7L4. Bracket geometry differs even between visually similar probes, so the pairing above is the starting point – not proof of fit.

When to replace the guide

  • Any crack in the bracket or channel, however small
  • Loose or unreliable locking onto the probe
  • A worn or scored channel that no longer tracks the needle cleanly
  • Warping or distortion after reprocessing
  • Discoloration combined with brittleness of the material

Confirm fit before ordering a replacement

  • Photograph the probe’s full manufacturer and model label and send it with the request.
  • Include photos of the existing guide or bracket and where it clips onto the probe.
  • Quote the reference number printed on the guide or bracket, if legible.
  • Specify the needle gauge range and whether you need a reusable or disposable configuration.
  • Note your sterilization or disinfection workflow so the right configuration is offered.

Similar probe names do not prove that two brackets are interchangeable – the attachment geometry and channel spec decide fit, so compatibility is confirmed against your exact probe label.

Ordering a replacement guide with a probe repair