Leapmed 10204202 Disposable Biopsy Needle Guide for GE 11L / 11L-D / 12L-RS +3 — Replacement

Replacement reference for the Leapmed 10204202 Disposable Biopsy Needle Guide for GE 11L / 11L-D / 12L-RS +3: confirm probe fit, guide type and needle gauge before ordering.

Get a Repair Quote for This Model

Send the label photo, fault description and console model — assessment confirmed in writing.

If the Leapmed 10204202 Disposable Biopsy Needle Guide for GE 11L / 11L-D / 12L-RS +3 on your probe is damaged, do not attempt to repair it: guides are precision accessories whose safety depends on exact geometry. This record helps you identify the matching replacement and confirm compatibility.

Catalogue name Leapmed 10204202 Disposable Biopsy Needle Guide for GE 11L / 11L-D / 12L-RS +3
Supplier Leapmed
Supplier reference 10204202, 10604202
Guide type Disposable Biopsy Needle Guide
Compatible probe references GE: 11L, 11L-D, 12L-RS, 12L-SC, L4-12t-RS, L6-12-RS
Source record Leapmed product record

Why biopsy guides are replaced rather than repaired

A biopsy guide constrains the needle path relative to the imaging plane. Cracks, deformation or channel wear shift that path, so a damaged guide is a safety issue rather than a repair candidate. Replacement restores the original geometry; repair cannot be verified to.

This reference is listed for the following probe(s): GE: 11L, 11L-D, 12L-RS, 12L-SC, L4-12t-RS, L6-12-RS. Bracket geometry differs even between visually similar probes, so the pairing above is the starting point – not proof of fit.

When to replace the guide

  • Visible cracks anywhere on the bracket or needle channel
  • Loose or unreliable locking onto the probe
  • The needle channel is worn, scored or lets the needle wander
  • Deformation after autoclaving or disinfection
  • Brittle, discolored material that flexes differently than new

Confirm fit before ordering a replacement

  • Photograph the probe’s full manufacturer and model label and send it with the request.
  • Photograph the current guide or bracket, including the attachment point on the probe.
  • State the guide or bracket reference if it is printed on the part.
  • State the needle gauges you work with and whether reusable or disposable is required.
  • Note your sterilization or disinfection workflow so the right configuration is offered.

Similar probe names do not prove that two brackets are interchangeable – the attachment geometry and channel spec decide fit, so compatibility is confirmed against your exact probe label.

Ordering a replacement guide with a probe repair

If the probe itself is also damaged, mention it in the same request – a probe repair and a replacement guide can be assessed and quoted together, which is usually faster than handling them separately.

The illustration is representative and is not a photograph of this exact guide. This record does not claim OEM authorization or universal fit. Compatibility, included components, availability and commercial terms are confirmed in writing for the exact probe and guide reference.