Leapmed 10207002 Disposable Biopsy Needle Guide for SonoSite HFL38x / L38 / L38e +1 — Replacement

Replacement reference for the Leapmed 10207002 Disposable Biopsy Needle Guide for SonoSite HFL38x / L38 / L38e +1: confirm probe fit, guide type and needle gauge before ordering.

Get a Repair Quote for This Model

Send the label photo, fault description and console model — assessment confirmed in writing.

If the Leapmed 10207002 Disposable Biopsy Needle Guide for SonoSite HFL38x / L38 / L38e +1 on your probe is damaged, do not attempt to repair it: guides are precision accessories whose safety depends on exact geometry. This record helps you identify the matching replacement and confirm compatibility.

Catalogue name Leapmed 10207002 Disposable Biopsy Needle Guide for SonoSite HFL38x / L38 / L38e +1
Supplier Leapmed
Supplier reference 10207002, 10607002
Guide type Disposable Biopsy Needle Guide
Compatible probe references SonoSite: HFL38x, L38, L38e, L38x
Source record Leapmed product record

Why biopsy guides are replaced rather than repaired

A biopsy guide constrains the needle path relative to the imaging plane. Cracks, deformation or channel wear shift that path, so a damaged guide is a safety issue rather than a repair candidate. Replacement restores the original geometry; repair cannot be verified to.

This reference is listed for the following probe(s): SonoSite: HFL38x, L38, L38e, L38x. Bracket geometry differs even between visually similar probes, so the pairing above is the starting point – not proof of fit.

When to replace the guide

  • Any crack in the bracket or channel, however small
  • The guide no longer clicks or locks firmly onto the probe
  • The needle channel is worn, scored or lets the needle wander
  • Deformation after autoclaving or disinfection
  • Brittle, discolored material that flexes differently than new

Confirm fit before ordering a replacement

  • Photograph the probe’s full manufacturer and model label and send it with the request.
  • Photograph the current guide or bracket, including the attachment point on the probe.
  • Quote the reference number printed on the guide or bracket, if legible.
  • State the needle gauges you work with and whether reusable or disposable is required.
  • Confirm sterilization or disinfection requirements in the request.

Similar probe names do not prove that two brackets are interchangeable – the attachment geometry and channel spec decide fit, so compatibility is confirmed against your exact probe label.

Ordering a replacement guide with a probe repair

If the probe itself is also damaged, mention it in the same request – a probe repair and a replacement guide can be assessed and quoted together, which is usually faster than handling them separately.

The illustration is representative and is not a photograph of this exact guide. This record does not claim OEM authorization or universal fit. Compatibility, included components, availability and commercial terms are confirmed in writing for the exact probe and guide reference.

WhatsApp Call Email Get a quote