Leapmed 10207502 Disposable Biopsy Needle Guide for BK Medical 8667 / E14C4 / 9067 — Replacement

Replacement reference for the Leapmed 10207502 Disposable Biopsy Needle Guide for BK Medical 8667 / E14C4 / 9067: confirm probe fit, guide type and needle gauge before ordering.

Get a Repair Quote for This Model

Send the label photo, fault description and console model — assessment confirmed in writing.

Biopsy guides like the Leapmed 10207502 Disposable Biopsy Needle Guide for BK Medical 8667 / E14C4 / 9067 are replaced rather than repaired – the bracket geometry and needle channel must stay within tolerance, and a worn or damaged guide should come out of service. Use this page to confirm fit before ordering a replacement.

Catalogue name Leapmed 10207502 Disposable Biopsy Needle Guide for BK Medical 8667 / E14C4 / 9067
Supplier Leapmed
Supplier reference 10207502, 10653402
Guide type Disposable Biopsy Needle Guide
Compatible probe references BK Medical: 8667, E14C4, 9067
Source record Leapmed product record

Why biopsy guides are replaced rather than repaired

Unlike the probe itself – where lenses, cables and connectors are routinely rebuilt – a guide is a single precision part. Once its bracket or channel is worn or cracked, tolerances are gone and the guide should be replaced, not patched.

This reference is listed for the following probe(s): BK Medical: 8667, E14C4, 9067. Bracket geometry differs even between visually similar probes, so the pairing above is the starting point – not proof of fit.

When to replace the guide

  • Visible cracks anywhere on the bracket or needle channel
  • The guide no longer clicks or locks firmly onto the probe
  • A worn or scored channel that no longer tracks the needle cleanly
  • Warping or distortion after reprocessing
  • Discoloration combined with brittleness of the material

Confirm fit before ordering a replacement

  • Photograph the probe’s full manufacturer and model label and send it with the request.
  • Include photos of the existing guide or bracket and where it clips onto the probe.
  • State the guide or bracket reference if it is printed on the part.
  • Specify the needle gauge range and whether you need a reusable or disposable configuration.
  • Note your sterilization or disinfection workflow so the right configuration is offered.

Similar probe names do not prove that two brackets are interchangeable – the attachment geometry and channel spec decide fit, so compatibility is confirmed against your exact probe label.

Ordering a replacement guide with a probe repair

Ordering a replacement guide alongside a probe repair? Include both in one request with the probe label photo – compatibility for the guide and repairability for the probe get confirmed in a single assessment.