Leapmed 120007 Reusable Biopsy Needle Guide for Chison D7L40L — Replacement

Replacement reference for the Leapmed 120007 Reusable Biopsy Needle Guide for Chison D7L40L: confirm probe fit, guide type and needle gauge before ordering.

Get a Repair Quote for This Model

Send the label photo, fault description and console model — assessment confirmed in writing.

The Leapmed 120007 Reusable Biopsy Needle Guide for Chison D7L40L is a positioning accessory, not a repairable device: when a guide is cracked, worn or no longer locks onto the probe, the correct action is replacement. This page helps you confirm the right replacement for your exact probe.

Catalogue name Leapmed 120007 Reusable Biopsy Needle Guide for Chison D7L40L
Guide supplier Leapmed
Supplier reference 120007
Guide type Reusable Biopsy Needle Guide
Compatible probe references Chison: D7L40L
Source record Supplier product record

Why biopsy guides are replaced rather than repaired

Unlike the probe itself – where lenses, cables and connectors are routinely rebuilt – a guide is a single precision part. Once its bracket or channel is worn or cracked, tolerances are gone and the guide should be replaced, not patched.

This reference is listed for the following probe(s): Chison: D7L40L. Bracket geometry differs even between visually similar probes, so the pairing above is the starting point – not proof of fit.

When to replace the guide

  • Visible cracks anywhere on the bracket or needle channel
  • Loose or unreliable locking onto the probe
  • The needle channel is worn, scored or lets the needle wander
  • Deformation after autoclaving or disinfection
  • Brittle, discolored material that flexes differently than new

Confirm fit before ordering a replacement

  • Photograph the probe’s full manufacturer and model label and send it with the request.
  • Include photos of the existing guide or bracket and where it clips onto the probe.
  • Quote the reference number printed on the guide or bracket, if legible.
  • Specify the needle gauge range and whether you need a reusable or disposable configuration.
  • Confirm sterilization or disinfection requirements in the request.

Similar probe names do not prove that two brackets are interchangeable – the attachment geometry and channel spec decide fit, so compatibility is confirmed against your exact probe label.

Ordering a replacement guide with a probe repair

Ordering a replacement guide alongside a probe repair? Include both in one request with the probe label photo – compatibility for the guide and repairability for the probe get confirmed in a single assessment.

The illustration is representative and is not a photograph of this exact guide. This record does not claim OEM authorization or universal fit. Compatibility, included components, availability and commercial terms are confirmed in writing for the exact probe and guide reference.

WhatsApp Call Email Get a quote