Leapmed 120233 Reusable Biopsy Needle Guide for Siemens BP9-4 — Replacement

Replacement reference for the Leapmed 120233 Reusable Biopsy Needle Guide for Siemens BP9-4: confirm probe fit, guide type and needle gauge before ordering.

Get a Repair Quote for This Model

Send the label photo, fault description and console model — assessment confirmed in writing.

The Leapmed 120233 Reusable Biopsy Needle Guide for Siemens BP9-4 is a positioning accessory, not a repairable device: when a guide is cracked, worn or no longer locks onto the probe, the correct action is replacement. This page helps you confirm the right replacement for your exact probe.

Catalogue name Leapmed 120233 Reusable Biopsy Needle Guide for Siemens BP9-4
Guide supplier Leapmed
Supplier reference 120233
Guide type Reusable Biopsy Needle Guide
Compatible probe references Siemens: BP9-4
Source record Supplier product record

Why biopsy guides are replaced rather than repaired

Guides take repeated mounting, sterilization and needle passes. Wear accumulates in the attachment points and needle channel, and there is no economical way to re-machine a worn guide back into tolerance. Replacement is the standard practice.

This reference is listed for the following probe(s): Siemens: BP9-4. Bracket geometry differs even between visually similar probes, so the pairing above is the starting point – not proof of fit.

When to replace the guide

  • Any crack in the bracket or channel, however small
  • The guide no longer clicks or locks firmly onto the probe
  • A worn or scored channel that no longer tracks the needle cleanly
  • Deformation after autoclaving or disinfection
  • Discoloration combined with brittleness of the material

Confirm fit before ordering a replacement

  • Send a clear photograph of the complete probe manufacturer and model label.
  • Include photos of the existing guide or bracket and where it clips onto the probe.
  • Quote the reference number printed on the guide or bracket, if legible.
  • Specify the needle gauge range and whether you need a reusable or disposable configuration.
  • Confirm sterilization or disinfection requirements in the request.

Similar probe names do not prove that two brackets are interchangeable – the attachment geometry and channel spec decide fit, so compatibility is confirmed against your exact probe label.

Ordering a replacement guide with a probe repair

Ordering a replacement guide alongside a probe repair? Include both in one request with the probe label photo – compatibility for the guide and repairability for the probe get confirmed in a single assessment.

The illustration is representative and is not a photograph of this exact guide. This record does not claim OEM authorization or universal fit. Compatibility, included components, availability and commercial terms are confirmed in writing for the exact probe and guide reference.

WhatsApp Call Email Get a quote