Akicare THREE Support & Replacement
Fault diagnosis and repair options for the Akicare THREE: failure modes, self-checks and what an assessment needs.
Table of Contents
PRODUCT DETAILS
Supply Ability
Supply Ability 5000 Unit/Units per Year
Packaging & Delivery
| Packaging Details | Common Box |
| Port | Hongkong |
| Picture Example: | ![]() ![]() |
DESCRIPTION
A failing Akicare THREE does not always mean buying a new probe. Use the fault table below to match what you are seeing on screen to a likely cause, then check what a repair assessment would need.
| Manufacturer | Akicare |
|---|---|
| Model | THREE |
Common failure modes for the THREE
Match what you are seeing against the table below. The right-hand column reflects how faults of this kind typically assess – the actual verdict always depends on the individual probe.
| What you see | Likely cause | Typically repairable? |
|---|---|---|
| Whole regions of the image blank across the array width | Widespread element or acoustic stack failure | Usually not economical |
| Outer cable sheath showing cracks, kinks or staining | Surface jacket wear – the conductors inside are often still good | Usually repairable |
| Pin damage or corrosion visible in the connector | Mechanical damage from forcing or dropping the connector | Usually repairable |
| Depth performance clearly below what this probe used to deliver | Ageing elements or lens delamination reducing acoustic output | Case by case |
| Cracked or dented housing | A drop or knock; housings are routinely replaced or resealed | Usually repairable |
| Intermittent signal that changes as the cable moves | One or more conductors broken inside the cable bundle | Case by case |
| Bubbles or lifting at the lens face | The lens separating from the acoustic stack underneath | Usually repairable |
Check these before you ship the probe
- Flex the cable gently along its length while imaging – intermittent dropout points to broken conductors.
- Check the strain reliefs at both ends for splits, stiffness or separation from the cable.
- Inspect the lens face under good light for cuts, bubbles, lifting edges or discoloration.
- Examine the connector for bent or corroded pins, cracks and a working locking mechanism.
- Run the system’s built-in probe test or element check if your console provides one.
Repair, exchange or replace — which applies to your THREE
For the THREE, think in terms of damage depth: surface and cable-level faults are usually repairable at a fraction of replacement cost; acoustic stack failures are evaluated case by case; extensive element loss generally means replacement. Send the symptoms and photos first – that determines the path before anything ships.
What we need to quote your THREE repair
- A clear photo of the complete manufacturer and model label on the probe
- A description of the fault: what you see on screen and when it started
- The ultrasound system (console) the probe is used with
- Screenshots or photos of the image problem, if the fault is visual
- Photos of any physical damage – lens, housing, cable or connector
Images shown are representative and are not photographs of an individual unit. Nothing on this page claims OEM authorization or guarantees universal fit. Whether a specific THREE can be repaired, and on what terms, is confirmed in writing once the probe has been assessed.
Company Profile



Sample Room

Customer Feedbacks




Exhibition




Production Process





Packing & Shipping




FAQ
Q: What is the MOQ?
A: 1pc.
Q: How about your delivery time?
A: 1~15 days depends on your order quantity.
Q: What is your terms of delivery?
A: DHL,TNT, EMS,UPS,FedEx,also can use customer’s freight forwarder.
Q: What is your terms of payment?
A: Western union, Alibaba Trade Assurance, T/T in advance.
Q: Do you test all your goods before delivery?
A: Yes, we have 100% tested our goods before delivery.
Q: What is your Service & Return policy?
A: If the probe is not compatible with your machine or there are any quality problem within 7 days after receiving the goods, please feel free to contact us. We will send a replacement probe or refund the payment to you.