Toshiba PSI-40VX Ultrasound Probe Repair
Fault diagnosis and repair options for the Toshiba PSI-40VX: failure modes, self-checks and what an assessment needs.
Table of Contents
PRODUCT DETAILS
Supply Ability
Supply Ability 5000 Unit/Units per Year
Packaging & Delivery
| Packaging Details | Common Box |
| Port | Hongkong |
| Picture Example: | ![]() ![]() |
DESCRIPTION
The Toshiba PSI-40VX is a common candidate for repair rather than replacement. This page lists its typical failure modes, self-checks you can run, and the details a repair lab needs from you.
| Manufacturer | Toshiba |
|---|---|
| Model | PSI-40VX |
| Probe type | Phased Array |
| Compatible systems | Canon Aplio i600 (TUS-AI600), Canon Aplio i700 (TUS-AI700), Canon Aplio i800 (TUS-AI800), Canon Aplio i900 (TUS-AI900) |
You will usually see the PSI-40VX running on Canon Aplio i600 (TUS-AI600), Canon Aplio i700 (TUS-AI700), Canon Aplio i800 (TUS-AI800), Canon Aplio i900 (TUS-AI900). Mention the console model with the fault description – connector and revision differences matter.
Compact phased-array heads such as the PSI-40VX are sensitive to element dropout at the sector edges, and round-the-clock cardiac use is hard on cables and strain reliefs.
Common failure modes for the PSI-40VX
Match what you are seeing against the table below. The right-hand column reflects how faults of this kind typically assess – the actual verdict always depends on the individual probe.
| What you see | Likely cause | Typically repairable? |
|---|---|---|
| Cuts, gouges or discoloration on the lens membrane | Mechanical wear or disinfectant damage to the lens | Usually repairable |
| Cracked or dented housing | Impact damage; housing can usually be replaced or resealed | Usually repairable |
| Cable jacket cracked, wrinkled or discolored | Jacket wear; conductors may still be intact underneath | Usually repairable |
| Intermittent signal that changes as the cable moves | Broken internal conductors in the cable | Case by case |
| Depth performance clearly below what this probe used to deliver | Ageing elements or lens delamination reducing acoustic output | Case by case |
| Air pockets or peeling visible on the acoustic lens | Lens delamination from the acoustic stack | Usually repairable |
| Fuzzy or noisy image that cleaning does not fix | A worn lens surface or elements beginning to degrade | Case by case |
| Sector image narrows or loses the apex | Element failure concentrated at the array edge | Case by case |
Check these before you ship the probe
- Photograph the complete manufacturer label – the exact revision matters for parts compatibility.
- Inspect the lens face under good light for cuts, bubbles, lifting edges or discoloration.
- Check the strain reliefs at both ends for splits, stiffness or separation from the cable.
- Compare penetration and uniformity against a known-good probe on the same preset.
- Examine the connector for bent or corroded pins, cracks and a working locking mechanism.
Repair, exchange or replace — which applies to your PSI-40VX
For the PSI-40VX, think in terms of damage depth: surface and cable-level faults are usually repairable at a fraction of replacement cost; acoustic stack failures are evaluated case by case; extensive element loss generally means replacement. Send the symptoms and photos first – that determines the path before anything ships.
What we need to quote your PSI-40VX repair
- A clear photo of the complete manufacturer and model label on the probe
- A description of the fault: what you see on screen and when it started
- The ultrasound system (console) the probe is used with
- Screenshots or photos of the image problem, if the fault is visual
- Photos of any physical damage – lens, housing, cable or connector
Product imagery on this page is representative of the PSI-40VX probe family and is not a photograph of your specific unit. This page does not claim OEM authorization or universal compatibility. Repair feasibility, turnaround and commercial terms are confirmed in writing after assessment of the actual probe.
Company Profile



Sample Room

Customer Feedbacks




Exhibition




Production Process





Packing & Shipping




FAQ
Q: What is the MOQ?
A: 1pc.
Q: How about your delivery time?
A: 1~15 days depends on your order quantity.
Q: What is your terms of delivery?
A: DHL,TNT, EMS,UPS,FedEx,also can use customer’s freight forwarder.
Q: What is your terms of payment?
A: Western union, Alibaba Trade Assurance, T/T in advance.
Q: Do you test all your goods before delivery?
A: Yes, we have 100% tested our goods before delivery.
Q: What is your Service & Return policy?
A: If the probe is not compatible with your machine or there are any quality problem within 7 days after receiving the goods, please feel free to contact us. We will send a replacement probe or refund the payment to you.