Wisonic C5-1B Biopsy Needle Guide (JSM-059) — Replacement
Replacement reference for the Wisonic C5-1B Biopsy Needle Guide (JSM-059): confirm probe fit, guide type and needle gauge before ordering.
Table of Contents
PRODUCT DETAILS
Supply Ability
Supply Ability 5000 Unit/Units per Year
Packaging & Delivery
| Packaging Details | Common Box |
| Port | Hongkong |
| Picture Example: | ![]() ![]() |
DESCRIPTION
Biopsy guides like the Wisonic C5-1B Biopsy Needle Guide (JSM-059) are replaced rather than repaired – the bracket geometry and needle channel must stay within tolerance, and a worn or damaged guide should come out of service. Use this page to confirm fit before ordering a replacement.
| Catalogue name | Wisonic C5-1B Biopsy Needle Guide (JSM-059) |
|---|---|
| Supplier | Wisonic |
Why biopsy guides are replaced rather than repaired
A biopsy guide constrains the needle path relative to the imaging plane. Cracks, deformation or channel wear shift that path, so a damaged guide is a safety issue rather than a repair candidate. Replacement restores the original geometry; repair cannot be verified to.
When to replace the guide
- Any crack in the bracket or channel, however small
- Loose or unreliable locking onto the probe
- The needle channel is worn, scored or lets the needle wander
- Deformation after autoclaving or disinfection
- Brittle, discolored material that flexes differently than new
Confirm fit before ordering a replacement
- Photograph the probe’s full manufacturer and model label and send it with the request.
- Photograph the current guide or bracket, including the attachment point on the probe.
- State the guide or bracket reference if it is printed on the part.
- State the needle gauges you work with and whether reusable or disposable is required.
- Confirm sterilization or disinfection requirements in the request.
Similar probe names do not prove that two brackets are interchangeable – the attachment geometry and channel spec decide fit, so compatibility is confirmed against your exact probe label.
Ordering a replacement guide with a probe repair
Ordering a replacement guide alongside a probe repair? Include both in one request with the probe label photo – compatibility for the guide and repairability for the probe get confirmed in a single assessment.
The illustration is representative and is not a photograph of this exact guide. This record does not claim OEM authorization or universal fit. Compatibility, included components, availability and commercial terms are confirmed in writing for the exact probe and guide reference.
Company Profile



Sample Room

Customer Feedbacks




Exhibition




Production Process





Packing & Shipping




FAQ
Q: What is the MOQ?
A: 1pc.
Q: How about your delivery time?
A: 1~15 days depends on your order quantity.
Q: What is your terms of delivery?
A: DHL,TNT, EMS,UPS,FedEx,also can use customer’s freight forwarder.
Q: What is your terms of payment?
A: Western union, Alibaba Trade Assurance, T/T in advance.
Q: Do you test all your goods before delivery?
A: Yes, we have 100% tested our goods before delivery.
Q: What is your Service & Return policy?
A: If the probe is not compatible with your machine or there are any quality problem within 7 days after receiving the goods, please feel free to contact us. We will send a replacement probe or refund the payment to you.