Ultrasound probe repair, verified before you ship.

Component-level transducer repair across 43 OEM brands — acoustic lens, array elements, micro-coax cable, 3D/4D motor assemblies, and TEE shafts. Send console fault photos first; if a probe is not economical to repair, we tell you not to ship it.

~5–7 working daysTypical in-house bench turnaround once received
Free return & dutiesWe prepay return courier & import customs — even if unrepairable
6–12 mo warrantyWritten coverage; every unit tested on live OEM ultrasound hosts

Request a Repair Assessment

Email or WhatsApp — one sentence or model number starts a written engineering check within one working day.

Email or WhatsApp — one is enough. We reply from Shenzhen within one working day.

Add model / system / country (optional)

We reply by email or WhatsApp. No obligation, and we do not quote before assessing the actual probe.

The Shenzhen repair floor — and the test report you receive

Not a trading broker. Every transducer is opened, rebuilt under magnification, and verified on real OEM ultrasound systems before dispatch. Below is our bench alongside an unedited customer test report excerpt (identity & pricing removed).

Microscope inspection workstation at Akicare Shenzhen ultrasound probe bench
Microscope bench for acoustic lens bonding, matching layer inspection, and micro-coax soldering.
Piezoelectric array element and cable repair under stereomicroscope
Component-level cable termination and array continuity verification under magnification.
Bank of live OEM ultrasound consoles used for post-repair transducer testing
In-house OEM console bank used to run live B-mode, Doppler, and 3D/4D sweep tests before return.
Desensitized Repair Report SonoSite C60xp/5-2 · P/N 04NLQ8

Issued 2 September 2025. Written test reports include incoming fault documentation, component action taken, and live console acoustic verification.

Incoming failed B-mode scan before ultrasound probe repair
Before — incoming fault
Post-repair live console acoustic scan showing restored uniformity
After — bench verified
Inspect the complete test report →

What are you seeing on the ultrasound screen?

Match the observed artifact or physical damage to its typical component root cause and bench repairability before requesting an assessment.

Observed Console / Physical Symptom Primary Root Cause Bench Feasibility What to Send First Technical Guide
Dark vertical bands or element dropout Dead piezoelectric crystals or fractured coaxial conductors High when cable/localized; screened by photo if array-wide Probe model + clear B-mode screen photo Dropout diagnosis →
Bubbles, peeling, or air pocket on face Acoustic lens delamination / chemical disinfectant swelling Routine bench repair when caught before fluid enters array Close-up of acoustic lens + model label Lens delamination →
Image flickers or cuts out when flexed Fatigued micro-coax shield or conductors inside strain relief Routine cable harness & strain relief rebuild Model + note of where flex triggers drop Cable repair →
3D/4D sweep freezes, clicks, or oil bubble Sweep motor, drive belt, encoder, or dome acoustic seal High — mechanical rebuild preserves intact 2D array Model (e.g. RAB6-D) + dome photo / error code 3D/4D volume repair →
Failed electrical leak test (TEE / endocavity) Insertion tube pinhole, bending rubber tear, or seam breach Stop clinical use immediately; sheath & seal restoration Model + leak tester reading / bite mark photo TEE probe repair →
Probe not recognized / bent ZIF pins Connector pin damage, latch wear, or ID EEPROM fault Routine connector & locking mechanism rebuild Connector face photo + host console model Connector repair →

How international probe repair works in practice

Clear division of responsibilities before anything leaves your hospital or service depot.

Your side (2 steps)

  • 1. Pre-shipment check: Send the probe label photo, console model, and screen artifact image (cover any patient identifiers). Live video call available on request.
  • 2. Inbound courier: Once we confirm repairability in writing, you book and pay inbound shipping to our Shenzhen lab.

Akicare’s side (4 commitments)

  • 1. Bench quote after inspection: Final price is confirmed only after hands-on bench diagnostics — never guessed from a photo.
  • 2. ~5–7 working days in-house: Repaired and validated on live OEM ultrasound systems; written test report issued on request.
  • 3. Free return shipping & duties worldwide: We arrange return courier, prepay freight and import duties, and clear customs — including when a probe cannot be repaired.
  • 4. 6–12 month written warranty: Confirmed with your quote; if the fault returns within warranty, we re-repair free of charge.
No loaner probes: Cross-border loaner logistics are not practical, so we do not supply loaner transducers. That is why we pre-screen by photo before shipment and keep in-house turnaround to about one week.

Working with clinics, biomeds, and dealers worldwide

Our own meeting and medical trade show photographs across Asia, Latin America, Europe, and the Middle East — no stock imagery.

Akicare at Hospital Expo Indonesia with medical imaging distributor partners
At a medical imaging exhibition
Akicare team visiting a customer company in Southeast Asia
At a customer company
Ultrasound probe case handed over at a customer meeting
Probe case handed over at a customer meeting
Going through the ultrasound probe catalogue with a customer
Going through the probe catalogue with a customer
Akicare representative shaking hands with an overseas ultrasound equipment customer
Meeting a customer at their office
Akicare at a medical imaging exhibition with customers and distributor partners
At a medical imaging exhibition

See all 47 photos →

Questions biomeds ask before shipping

Can a broken ultrasound probe be repaired?

Often yes. Acoustic lens delamination, housing cracks, cable/strain relief breaks, connector pin damage, and 3D/4D mechanical sweep failures are routine repairs. Widespread piezoelectric array failure is usually not economical — which we screen before you ship.

How do I know if my probe is worth repairing before paying freight?

Send the model label and a photo of the B-mode screen artifact (or request a quick video call). If the symptom indicates unrepairable array-wide crystal loss, we advise you not to ship.

Who pays for shipping and customs duties?

You arrange and pay inbound courier shipping to Shenzhen. Return shipping costs you nothing: Akicare arranges return delivery, prepays freight and import duties, and handles customs paperwork — including when the probe could not be repaired.

Do you claim OEM authorization?

No. Akicare is an independent component-level repair laboratory in Shenzhen. Brand names (GE, Philips, Mindray, Siemens, Canon/Toshiba, Hitachi Aloka, Samsung, etc.) are used solely to identify probe compatibility and repair scope.

WhatsApp Request Assessment