AKICARE BENCH LAB · SHENZHEN · 3,011 DOCUMENTED MODELS

Ultrasound probe repair, verified before you ship.

Component-level transducer repair across 43 OEM brands — acoustic lens, array elements, micro-coax cable, 3D/4D motor assemblies, and TEE shafts. Send console fault photos first; if a probe is not economical to repair, we tell you not to ship it.

~5–7 working daysTypical in-house bench turnaround once received
Free return & dutiesWe prepay return courier & import customs — even if unrepairable
6–12 mo warrantyWritten coverage; every unit tested on live OEM ultrasound hosts

Request a Repair Assessment

Email or WhatsApp — one sentence or model number starts a written engineering check within one working day.

Email or WhatsApp — one is enough. We reply from Shenzhen within one working day.

Add model / system / country (optional)

We reply by email or WhatsApp. No obligation, and we do not quote before assessing the actual probe.

01 · BENCH PROOF & REAL DELIVERABLE

The Shenzhen repair floor — and the test report you receive

Not a trading broker. Every transducer is opened, rebuilt under magnification, and verified on real OEM ultrasound systems before dispatch. Below is our bench alongside an unedited customer test report excerpt (identity & pricing removed).

Microscope inspection workstation at Akicare Shenzhen ultrasound probe bench
Microscope bench for acoustic lens bonding, matching layer inspection, and micro-coax soldering.
Piezoelectric array element and cable repair under stereomicroscope
Component-level cable termination and array continuity verification under magnification.
Bank of live OEM ultrasound consoles used for post-repair transducer testing
In-house OEM console bank used to run live B-mode, Doppler, and 3D/4D sweep tests before return.
Desensitized Repair Report SONOSITE C60XP/5-2 · P/N 04NLQ8

Issued 2 September 2025. Written test reports include incoming fault documentation, component action taken, and live console acoustic verification.

Incoming failed B-mode scan before ultrasound probe repair
BEFORE · INCOMING FAULT
Post-repair live console acoustic scan showing restored uniformity
AFTER · BENCH VERIFIED
Inspect the complete test report →
02 · SYMPTOM-TO-FEASIBILITY REFERENCE

What are you seeing on the ultrasound screen?

Match the observed artifact or physical damage to its typical component root cause and bench repairability before requesting an assessment.

Observed Console / Physical Symptom Primary Root Cause Bench Feasibility What to Send First Technical Guide
Dark vertical bands or element dropout Dead piezoelectric crystals or fractured coaxial conductors High when cable/localized; screened by photo if array-wide Probe model + clear B-mode screen photo Dropout diagnosis →
Bubbles, peeling, or air pocket on face Acoustic lens delamination / chemical disinfectant swelling Routine bench repair when caught before fluid enters array Close-up of acoustic lens + model label Lens delamination →
Image flickers or cuts out when flexed Fatigued micro-coax shield or conductors inside strain relief Routine cable harness & strain relief rebuild Model + note of where flex triggers drop Cable repair →
3D/4D sweep freezes, clicks, or oil bubble Sweep motor, drive belt, encoder, or dome acoustic seal High — mechanical rebuild preserves intact 2D array Model (e.g. RAB6-D) + dome photo / error code 3D/4D volume repair →
Failed electrical leak test (TEE / endocavity) Insertion tube pinhole, bending rubber tear, or seam breach Stop clinical use immediately; sheath & seal restoration Model + leak tester reading / bite mark photo TEE probe repair →
Probe not recognized / bent ZIF pins Connector pin damage, latch wear, or ID EEPROM fault Routine connector & locking mechanism rebuild Connector face photo + host console model Connector repair →
04 · CROSS-BORDER LOGISTICS & HONEST TERMS

How international probe repair works in practice

Clear division of responsibilities before anything leaves your hospital or service depot.

Your side (2 steps)

  • 1. Pre-shipment check: Send the probe label photo, console model, and screen artifact image (cover any patient identifiers). Live video call available on request.
  • 2. Inbound courier: Once we confirm repairability in writing, you book and pay inbound shipping to our Shenzhen lab.

Akicare’s side (4 commitments)

  • 1. Bench quote after inspection: Final price is confirmed only after hands-on bench diagnostics — never guessed from a photo.
  • 2. ~5–7 working days in-house: Repaired and validated on live OEM ultrasound systems; written test report issued on request.
  • 3. Free return shipping & duties worldwide: We arrange return courier, prepay freight and import duties, and clear customs — including when a probe cannot be repaired.
  • 4. 6–12 month written warranty: Confirmed with your quote; if the fault returns within warranty, we re-repair free of charge.
No loaner probes: Cross-border loaner logistics are not practical, so we do not supply loaner transducers. That is why we pre-screen by photo before shipment and keep in-house turnaround to about one week.
05 · FIELD & EXHIBITION VERIFICATION

Working with clinics, biomeds, and dealers worldwide

Our own meeting and medical trade show photographs across Asia, Latin America, Europe, and the Middle East — no stock imagery.

Akicare at Hospital Expo Indonesia with medical imaging distributor partners
At a medical imaging exhibition
Akicare team visiting a customer company in Southeast Asia
At a customer company
Ultrasound probe case handed over at a customer meeting
Probe case handed over at a customer meeting
Going through the ultrasound probe catalogue with a customer
Going through the probe catalogue with a customer
Akicare representative shaking hands with an overseas ultrasound equipment customer
Meeting a customer at their office
Akicare at a medical imaging exhibition with customers and distributor partners
At a medical imaging exhibition

See all 47 photos →

06 · COMMON QUESTIONS

Questions biomeds ask before shipping

Can a broken ultrasound probe be repaired?

Often yes. Acoustic lens delamination, housing cracks, cable/strain relief breaks, connector pin damage, and 3D/4D mechanical sweep failures are routine repairs. Widespread piezoelectric array failure is usually not economical — which we screen before you ship.

How do I know if my probe is worth repairing before paying freight?

Send the model label and a photo of the B-mode screen artifact (or request a quick video call). If the symptom indicates unrepairable array-wide crystal loss, we advise you not to ship.

Who pays for shipping and customs duties?

You arrange and pay inbound courier shipping to Shenzhen. Return shipping costs you nothing: Akicare arranges return delivery, prepays freight and import duties, and handles customs paperwork — including when the probe could not be repaired.

Do you claim OEM authorization?

No. Akicare is an independent component-level repair laboratory in Shenzhen. Brand names (GE, Philips, Mindray, Siemens, Canon/Toshiba, Hitachi Aloka, Samsung, etc.) are used solely to identify probe compatibility and repair scope.

WhatsApp Request Assessment