This page covers the Toshiba PET-805LA (12LI4) from a repair perspective: the failure modes we see on this class of probe, how to check the probe yourself, and what information gets you an accurate repair quote.
| Manufacturer | Toshiba |
|---|---|
| Model | PET-805LA (12LI4) |
| Probe type | Linear array |
| Compatible systems | Canon Aplio i600 (TUS-AI600), Canon Aplio i700 (TUS-AI700), Canon Aplio i800 (TUS-AI800), Canon Aplio i900 (TUS-AI900), Toshiba Aplio 400 (TUS-A400), Toshiba Aplio 500 (TUS-A500) |
You will usually see the PET-805LA (12LI4) running on Canon Aplio i600 (TUS-AI600), Canon Aplio i700 (TUS-AI700), Canon Aplio i800 (TUS-AI800), Canon Aplio i900 (TUS-AI900), Toshiba Aplio 400 (TUS-A400) and other listed systems. Mention the console model with the fault description – connector and revision differences matter.
On linear probes such as the PET-805LA (12LI4), superficial imaging workloads put steady stress on the lens membrane and strain relief; the element electronics tend to outlast the mechanical parts.
Common failure modes for the PET-805LA (12LI4)
Match what you are seeing against the table below. The right-hand column reflects how faults of this kind typically assess – the actual verdict always depends on the individual probe.
| What you see | Likely cause | Typically repairable? |
|---|---|---|
| Vertical shadowing or missing scan lines on screen | Element dropout, or a conductor break inside the cable | Case by case |
| Image cuts out when the cable is flexed | Broken internal conductors in the cable | Case by case |
| Fuzzy or noisy image that cleaning does not fix | Lens wear or early element degradation | Case by case |
| Cracked or dented housing | Impact damage; housing can usually be replaced or resealed | Usually repairable |
| Air pockets or peeling visible on the acoustic lens | The lens separating from the acoustic stack underneath | Usually repairable |
| Outer cable sheath showing cracks, kinks or staining | Jacket wear; conductors may still be intact underneath | Usually repairable |
| Connector lock broken or hardware missing | Mechanical damage to the connector shell | Usually repairable |
Check these before you ship the probe
- Compare penetration and uniformity against a known-good probe on the same preset.
- Photograph the complete manufacturer label – the exact revision matters for parts compatibility.
- Inspect the lens face under good light for cuts, bubbles, lifting edges or discoloration.
- Check the strain reliefs at both ends for splits, stiffness or separation from the cable.
- Examine the connector for bent or corroded pins, cracks and a working locking mechanism.
Repair, exchange or replace — which applies to your PET-805LA (12LI4)
Whether a PET-805LA (12LI4) is worth repairing depends on the damage scope: localized lens, cable, strain relief and connector faults are routine repairs, while widespread element loss usually is not economical. An exchange unit can bridge the gap when downtime matters, and replacement becomes rational when repair cost approaches replacement value. A written assessment settles this per probe – condition, not model, decides it.
What we need to quote your PET-805LA (12LI4) repair
- A clear photo of the complete manufacturer and model label on the probe
- A description of the fault: what you see on screen and when it started
- The ultrasound system (console) the probe is used with
- Screenshots or photos of the image problem, if the fault is visual
- Photos of any physical damage – lens, housing, cable or connector
Product imagery on this page is representative of the PET-805LA (12LI4) probe family and is not a photograph of your specific unit. This page does not claim OEM authorization or universal compatibility. Repair feasibility, turnaround and commercial terms are confirmed in writing after assessment of the actual probe.






Reviews
There are no reviews yet.