Hitachi Aloka EUP-C715 Biopsy Needle Guide (HSM-059) — Replacement

Replacement reference for the Hitachi Aloka EUP-C715 Biopsy Needle Guide (HSM-059): confirm probe fit, guide type and needle gauge before ordering.

Table of Contents

PRODUCT DETAILS

Supply Ability

Supply Ability5000 Unit/Units per Year

Packaging & Delivery

Packaging DetailsCommon Box
PortHongkong
Picture Example:Ultrasound Probes Akicare Ultrasound Probes Akicare

DESCRIPTION

If the Hitachi Aloka EUP-C715 Biopsy Needle Guide (HSM-059) on your probe is damaged, do not attempt to repair it: guides are precision accessories whose safety depends on exact geometry. This record helps you identify the matching replacement and confirm compatibility.

Catalogue name Hitachi Aloka EUP-C715 Biopsy Needle Guide (HSM-059)
Supplier Hitachi Aloka

Why biopsy guides are replaced rather than repaired

A biopsy guide constrains the needle path relative to the imaging plane. Cracks, deformation or channel wear shift that path, so a damaged guide is a safety issue rather than a repair candidate. Replacement restores the original geometry; repair cannot be verified to.

When to replace the guide

  • Visible cracks anywhere on the bracket or needle channel
  • Loose or unreliable locking onto the probe
  • The needle channel is worn, scored or lets the needle wander
  • Deformation after autoclaving or disinfection
  • Brittle, discolored material that flexes differently than new

Confirm fit before ordering a replacement

  • Photograph the probe’s full manufacturer and model label and send it with the request.
  • Photograph the current guide or bracket, including the attachment point on the probe.
  • Quote the reference number printed on the guide or bracket, if legible.
  • State the needle gauges you work with and whether reusable or disposable is required.
  • Confirm sterilization or disinfection requirements in the request.

Similar probe names do not prove that two brackets are interchangeable – the attachment geometry and channel spec decide fit, so compatibility is confirmed against your exact probe label.

Ordering a replacement guide with a probe repair

If the probe itself is also damaged, mention it in the same request – a probe repair and a replacement guide can be assessed and quoted together, which is usually faster than handling them separately.

The illustration is representative and is not a photograph of this exact guide. This record does not claim OEM authorization or universal fit. Compatibility, included components, availability and commercial terms are confirmed in writing for the exact probe and guide reference.

Company Profile

Akicare now provides one-stop total solution for new ultrasound probes,ultrasound probe repair service and biopsy guide for ultrasound probes.We have exported our products to more than 120 countries all over the world.
Company Advantage
1.High quality.
2.Fast shipping.
3.Over Ten years old experience.
4.Covering most of ultrasound probe models.

Sample Room

Customer Feedbacks

Exhibition

Production Process

Packing & Shipping

FAQ

Q: What is the MOQ?

A: 1pc.

Q: How about your delivery time?

A: 1~15 days depends on your order quantity.

Q: What is your terms of delivery?

A: DHL,TNT, EMS,UPS,FedEx,also can use customer’s freight forwarder. 

Q: What is your terms of payment?

A: Western union, Alibaba Trade Assurance, T/T in advance. 

Q: Do you test all your goods before delivery? 

A: Yes, we have 100% tested our goods before delivery. 

Q: What is your Service & Return policy? 

A: If the probe is not compatible with your machine or there are any quality problem within 7 days after receiving the goods, please feel free to contact us. We will send a replacement probe or refund the payment to you.

Send Me