The CIVCO AccuSITE Out-of-Plane Ultrasound Needle Guides is a positioning accessory, not a repairable device: when a guide is cracked, worn or no longer locks onto the probe, the correct action is replacement. This page helps you confirm the right replacement for your exact probe.
| Catalogue name | CIVCO AccuSITE Out-of-Plane Ultrasound Needle Guides |
|---|---|
| Supplier | CIVCO |
| Supplier reference | 667-126, 671-002, 671-003, 674-068, 680-132, 680-134, 680-162, 680-164, 680-170, 680-176, 680-186, 683-002, 698-005, 698-006, 698-012 |
| Guide type | Biopsy Needle Guide |
| Compatible probe references | Canon: 11L4, 12L4, 18L7, i11LX3, i18LX5, i24LX8, i9LX2, PLT-1204BT, PLU-1204BT Esaote: SB2C41 GE: 12L-RS, 12L-SC, L4-12t-RS Philips: L12-4, S5-1, S5-2 Siemens: L13-5, L17-5, L8-3 SonoSite: HFL38, HFL38x, L19-5, L38, L38e, L38x Teleflex: DLX-200-USP Terason: 12L5V, 15L4 |
| Source record | CIVCO product record |
Why biopsy guides are replaced rather than repaired
A biopsy guide constrains the needle path relative to the imaging plane. Cracks, deformation or channel wear shift that path, so a damaged guide is a safety issue rather than a repair candidate. Replacement restores the original geometry; repair cannot be verified to.
This reference is listed for the following probe(s): Canon: 11L4, 12L4, 18L7, i11LX3, i18LX5, i24LX8, i9LX2, PLT-1204BT, PLU-1204BT Esaote: SB2C41 GE: 12L-RS, 12L-SC, L4-12t-RS Philips: L12-4, S5-1, S5-2 Siemens: L13-5, L17-5, L8-3 SonoSite: HFL38, HFL38x, L19-5, L38, L38e, L38x Teleflex: DLX-200-USP Terason: 12L5V, 15L4. Bracket geometry differs even between visually similar probes, so the pairing above is the starting point – not proof of fit.
When to replace the guide
- Visible cracks anywhere on the bracket or needle channel
- Loose or unreliable locking onto the probe
- The needle channel is worn, scored or lets the needle wander
- Deformation after autoclaving or disinfection
- Discoloration combined with brittleness of the material
Confirm fit before ordering a replacement
- Photograph the probe’s full manufacturer and model label and send it with the request.
- Photograph the current guide or bracket, including the attachment point on the probe.
- State the guide or bracket reference if it is printed on the part.
- Specify the needle gauge range and whether you need a reusable or disposable configuration.
- Confirm sterilization or disinfection requirements in the request.
Similar probe names do not prove that two brackets are interchangeable – the attachment geometry and channel spec decide fit, so compatibility is confirmed against your exact probe label.
Ordering a replacement guide with a probe repair
If the probe itself is also damaged, mention it in the same request – a probe repair and a replacement guide can be assessed and quoted together, which is usually faster than handling them separately.
The illustration is representative and is not a photograph of this exact guide. This record does not claim OEM authorization or universal fit. Compatibility, included components, availability and commercial terms are confirmed in writing for the exact probe and guide reference.